MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2006.02.046

Медицинская библиотека · Gastrointestinal endoscopy · 2006

The Neo-Papilla: a new modification of porcine ex vivo simulators for ERCP training (with videos).

Matthes Kai, Cohen Jonathan

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Computer simulators, live pigs, and ex vivo porcine simulators are used for training in ERCP. The location of the porcine biliary orifice in the proximal duodenum is dissimilar to human anatomy, making the endoscopy experience less realistic. In addition, in native porcine anatomy, the pancreatic duct enters the duodenum distal to the biliary orifice, limiting the teaching of pancreatic techniques and selective duct cannulation.

OBJECTIVE

To overcome these limitations, we aimed to construct a Neo-Papilla that could be incorporated into an ex vivo model.

DESIGN

We attached chicken heart tissue to the porcine duodenum, with integrated porcine arteries that resembled an artificial common bile duct and a pancreatic duct.

SETTING

The simulator was presented and evaluated at 2 major GI endoscopy conferences.

MAIN OUTCOME MEASUREMENTS: The feasibility and the realism of this prototype was tested by 9 recognized ERCP experts who rated this model in comparison to other teaching models for ERCP by recollection of prior experience.

RESULTS

The Neo-Papilla was more prominent and more distally located than the native porcine papilla. The experts rated this modification superior to existing models in its usefulness as an educational tool.

LIMITATIONS: Pilot study.

CONCLUSIONS

We demonstrated the technical feasibility of a real-tissue Neo-Papilla modification of porcine ex vivo simulators, more closely approximating the natural anatomy. This new model should facilitate ERCP training. Formal validation studies are warranted.

Для цитирования: Matthes Kai, Cohen Jonathan. The Neo-Papilla: a new modification of porcine ex vivo simulators for ERCP training (with videos).. Gastrointestinal endoscopy. 2006. DOI: 10.1016/j.gie.2006.02.046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.