MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-019-01979-4

Медицинская библиотека · Abdominal radiology (New York) · 2019

Interobserver agreement of computed tomography reporting standards for chronic pancreatitis.

Razek Ahmed Abdel Khalek Abdel, Elfar Elsayed, Abubacker Shefeek

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To assess the interobserver agreement of computed tomography (CT) reporting standards for chronic pancreatitis (CP).

SUBJECTS AND

METHODS

Retrospective analysis of CT of 47 patients (33 males and 11 females, age range 36 to 56 years) with CP who presented with abdominal pain (n = 41), steatorrhea (n = 37), and glucose intolerance (n = 31). The patients underwent CT study using a 16-multidetector CT scanner with a pancreatic protocol including a nonenhanced scan followed by pancreatic phase at 35 s and portal venous phase at 65 s after intravenous injection of nonionic contrast medium. Image analysis was performed by two radiologists according to reporting standards for CP.

RESULTS

There was excellent interobserver agreement (84.8 %) between the two reviewers in CT reporting standards for CP (K = 0.80, 95 % CI 0.75-0.85, P = 0.001). There was good interobserver agreement for pancreatic duct (PD) caliber (K = 0.71, 95 % CI 0.56-0.87, P = 0.001), PD contour (K = 0.76, 95 % CI 0.61-0.91, P = 0.001), PD stricture (K = 0.070, 95 % CI 0.53-0.88, P = 0.001), and distribution of findings (K = 0.69, 95 % CI 0.51-0.86, P = 0.001). There was excellent interobserver agreement for intraductal calculi (K = 0.84, 95 % CI 0.68-0.98, P = 0.001), pancreatic calcifications (K = 0.86, 95 % CI 0.84-0.98, P = 0.001), and pancreatic diameter (K = 0.87, 95 % CI 0.75-0.99, P = 0.001).

CONCLUSION

CT reporting standards for CP is a reliable method for diagnosis of patients with CP.

Для цитирования: Razek Ahmed Abdel Khalek Abdel, Elfar Elsayed, Abubacker Shefeek. Interobserver agreement of computed tomography reporting standards for chronic pancreatitis.. Abdominal radiology (New York). 2019. DOI: 10.1007/s00261-019-01979-4.

Предметные рубрики MeSH