MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.26612

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2019

Patient respiratory-triggered quantitative T2 mapping in the pancreas.

Vietti Violi Naïk, Hilbert Tom, Bastiaansen Jessica A M, Knebel Jean-Francois, Ledoux Jean-Baptiste, Stemmer Alto, Meuli Reto, Kober Tobias, Schmidt Sabine

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Long acquisition times and motion sensitivity limit T2 mapping in the abdomen. Accelerated mapping at 3 T may allow for quantitative assessment of diffuse pancreatic disease in patients during free-breathing.

PURPOSE: To test the feasibility of respiratory-triggered quantitative T2 analysis in the pancreas and correlate T2 -values with age, body mass index, pancreatic location, main pancreatic duct dilatation, and underlying pathology.

STUDY TYPE: Retrospective single-center pilot study.

POPULATION: Eighty-eight adults.

FIELD STRENGTH/SEQUENCE: Ten-fold accelerated multiecho-spin-echo 3 T MRI sequence to quantify T2 at 3 T.

ASSESSMENT: Two radiologists independently delineated three regions of interest inside the pancreatic head, body, and tail for each acquisition. Means and standard deviations for T2 values in these regions were determined. T2 -value variation with demographic data, intraparenchymal location, pancreatic duct dilation, and underlying pancreatic disease was assessed.

STATISTICAL TESTS: Interreader reliability was determined by calculating the interclass coefficient (ICCs). T2 values were compared for different pancreatic locations by analysis of variance (ANOVA). Interpatient associations between T2 values and demographical, clinical, and radiological data were calculated (ANOVA).

RESULTS

The accelerated T2 mapping sequence was successfully performed in all participants (mean acquisition time, 2:48 ± 0:43 min). Low T2 value variability was observed across all patients (intersubject) (head: 60.2 ± 8.3 msec, body: 63.9 ± 11.5 msec, tail: 66.8 ± 16.4 msec). Interreader agreement was good (ICC, 0.82, 95% confidence interval: 0.77-0.86). T2 -values differed significantly depending on age (P < 0.001), location (P < 0.001), main pancreatic duct dilatation (P < 0.001), and diffuse pancreatic disease (P < 0.03).

DATA

CONCLUSION

The feasibility of accelerated T2 mapping at 3 T in moving abdominal organs was demonstrated in the pancreas, since T2 values were stable and reproducible. In the pancreatic parenchyma, T2 -values were significantly dependent on demographic and clinical parameters.

LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:410-416.

Для цитирования: Vietti Violi Naïk, Hilbert Tom, Bastiaansen Jessica A M, Knebel Jean-Francois, Ledoux Jean-Baptiste, Stemmer Alto, Meuli Reto, Kober Tobias, Schmidt Sabine. Patient respiratory-triggered quantitative T2 mapping in the pancreas.. Journal of magnetic resonance imaging : JMRI. 2019. DOI: 10.1002/jmri.26612.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.