MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jhbp.604

Медицинская библиотека · Journal of hepato-biliary-pancreatic sciences · 2019

Bio-absorbable sealants for reinforcing the pancreatic stump after distal pancreatectomy are critical.

Kühlbrey Christian M, Kasper Steivan, Chikhladze Sophia, Seifert Gabriel, Hopt Ulrich T, Fichtner-Feigl Stefan, Wittel Uwe A

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Bio-absorbable sealants are widely used to reduce the rate and severity of postoperative pancreatic fistulas after distal pancreatectomy. However, numerous clinical trials have failed to demonstrate their clinical benefit. We therefore investigated stability and bio-compatibility of absorbable sealants in vitro and in vivo.

METHODS

In vitro, polymerized compounds were incubated in pancreatic juice before their stability was tested. In vivo, two compounds were used to seal the pancreatic stump after distal pancreatectomy in nine pigs. Burst pressure of the pancreatic stump, surgical outcome, histology of the pancreatic stump, systemic inflammation, and drain fluid was examined.

RESULTS

Products based on fibrin or collagen were unstable in the presence of active pancreatic enzymes and completely dissolved within 2 h. Sealants using chemical cross-linking of proteins showed improved stability for 7 days. In vivo, application of polyethylenglycol-based sealant leads to complete closure of the pancreatic duct after 5 days, while a glutaraldehyde-based sealant prevented physiological closure of the pancreatic main duct.

CONCLUSIONS

Many compounds used clinically to reinforce the pancreatic stump after distal pancreatectomy are inadequate due to instability in the presence of pancreatic enzymes. While selected bio-absorbable sealants inhibited the natural healing of the pancreatic stump, polyethylenglycol-based sealants should be tested in further clinical trials.

Для цитирования: Kühlbrey Christian M, Kasper Steivan, Chikhladze Sophia, Seifert Gabriel, Hopt Ulrich T, Fichtner-Feigl Stefan, Wittel Uwe A. Bio-absorbable sealants for reinforcing the pancreatic stump after distal pancreatectomy are critical.. Journal of hepato-biliary-pancreatic sciences. 2019. DOI: 10.1002/jhbp.604.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.