Face and construct validity of a novel mechanical ERCP simulator.

van der Wiel Sophia E, Koch Arjun D, Bruno Marco J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND STUDY AIMS: Simulation-based training has become an important pillar in competence-based medicine. However, limited data are available on use of simulators in training for endoscopic retrograde cholangiopancreatography (ERCP). We aimed to determine the face and construct validity of the Boškoski-Costamagna mechanical ERCP Trainer, and to assess its didactic value, as judged by experts.

METHODS

Participants were divided into four groups based on ERCP lifetime experience: novices, intermediate, experienced, and experts. Participants performed several standardized assignments on the simulator. Outcome parameters included times to complete the procedure, ability to cannulate both ducts, number of attempts to cannulate the common bile duct and pancreatic duct, number of inadvertent pancreatic duct cannulations, successful stent placement, and successful stone extraction. All experts filled out a questionnaire on the simulator's realism and didactic value.

RESULTS

Novices (n = 11) completed the total procedure in 21:09 (min:sec), intermediates (n = 5) in 10:58, experienced (n = 8) in 06:42 and experts (n = 22) in 06:05. Experts were significantly faster than novices (Kruskal-Wallis test P  < 0.000). Experts rated the realism of the simulator 7.12 on a 10-point Likert scale. The simulator's potential as a tool for training novices was rated 3.91 on a four-point Likert scale, and there was a high agreement among experts to include the simulator in the training of novice endoscopists (3.86 on a four-point Likert scale).

CONCLUSIONS

The novel Boškoski-Costamagna ERCP simulator demonstrates good face and construct validity. ERCP experts highly agree on the didactic value and added value of this simulator in the training curriculum for novice endoscopists.

Для цитирования: van der Wiel Sophia E, Koch Arjun D, Bruno Marco J. Face and construct validity of a novel mechanical ERCP simulator.. Endoscopy international open. 2018. DOI: 10.1055/s-0044-101754.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.