MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mp.16335

Медицинская библиотека · Medical physics · 2023

Scatter correction of 4D cone beam computed tomography to detect dosimetric effects due to anatomical changes in proton therapy for lung cancer.

Schmitz Henning, Rabe Moritz, Janssens Guillaume, Rit Simon, Parodi Katia, Belka Claus, Kamp Florian, Landry Guillaume, Kurz Christopher

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The treatment of moving tumor entities is expected to have superior clinical outcomes, using image-guided adaptive intensity-modulated proton therapy (IMPT).

PURPOSE: For 21 lung cancer patients, IMPT dose calculations were performed on scatter-corrected 4D cone beam CTs (4DCBCTcor ) to evaluate their potential for triggering treatment adaptation. Additional dose calculations were performed on corresponding planning 4DCTs and day-of-treatment 4D virtual CTs (4DvCTs).

METHODS

A 4DCBCT correction workflow, previously validated on a phantom, generates 4DvCT (CT-to-CBCT deformable registration) and 4DCBCTcor images (projection-based correction using 4DvCT as a prior) with 10 phase bins, using day-of-treatment free-breathing CBCT projections and planning 4DCT images as input. Using a research planning system, robust IMPT plans administering eight fractions of 7.5 Gy were created on a free-breathing planning CT (pCT) contoured by a physician. The internal target volume (ITV) was overridden with muscle tissue. Robustness settings for range and setup uncertainties were 3% and 6 mm, and a Monte Carlo dose engine was used. On every phase of planning 4DCT, day-of-treatment 4DvCT, and 4DCBCTcor , the dose was recalculated. For evaluation, image analysis as well as dose analysis were performed using mean error (ME) and mean absolute error (MAE) analysis, dose-volume histogram (DVH) parameters, and 2%/2-mm gamma pass rate analysis. Action levels (1.6% ITV D98 and 90% gamma pass rate) based on our previous phantom validation study were set to determine which patients had a loss of dosimetric coverage.

RESULTS

Quality enhancements of 4DvCT and 4DCBCTcor over 4DCBCT were observed. ITV D98% and bronchi D2% had its largest agreement for 4DCBCTcor -4DvCT, and the largest gamma pass rates (>94%, median 98%) were found for 4DCBCTcor -4DvCT. Deviations were larger and gamma pass rates were smaller for 4DvCT-4DCT and 4DCBCTcor -4DCT. For five patients, deviations were larger than the action levels, suggesting substantial anatomical changes between pCT and CBCT projections acquisition.

CONCLUSIONS

This retrospective study shows the feasibility of daily proton dose calculation on 4DCBCTcor for lung tumor patients. The applied method is of clinical interest as it generates up-to-date in-room images, accounting for breathing motion and anatomical changes. This information could be used to trigger replanning.

Для цитирования: Schmitz Henning, Rabe Moritz, Janssens Guillaume, Rit Simon, Parodi Katia, Belka Claus, Kamp Florian, Landry Guillaume, Kurz Christopher. Scatter correction of 4D cone beam computed tomography to detect dosimetric effects due to anatomical changes in proton therapy for lung cancer.. Medical physics. 2023. DOI: 10.1002/mp.16335.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.