MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcms.2018.05.036

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2018

Validation of a simulator for cranial graft lift training: Face, content, and construct validity.

Hollensteiner Marianne, Malek Michael, Augat Peter, Fürst David, Schrödl Falk, Hunger Stefan, Esterer Benjamin, Gabauer Stefan, Schrempf Andreas

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Surgical skills can be improved through practical exercise. The use of specimens, human as well as animal, or live animals for surgical training is limited due to ethical concerns. Drawbacks of simulators are costs, fidelity and creditibility. Thus, simulators must be evaluated objectively to determine their validity before they can be used as teaching modalities. The aim of this study was to verify the face content and construct validity of a novel model-based simulator for lifting tabula externa transplants from the parietal skull.

MATERIALS AND

METHODS

Participants were invited to perform a tabula externa graft lift during a training session on the simulator. Task performance was analyzed with a standardized assessment tool evaluating realism and appropriateness. Specialist ratings were used to evaluate the performance of the participants. This was an exploratory study using a questionnaire, at Kepler University Hospital, Linz, Austria, a university hospital. According to their expertise in craniomaxillofacial surgery, 17 participants were subdivided into 3 groups: 8 novices, 7 experts and 2 raters.

RESULTS

The face validity (realism) obtained an average score of 4.2 of a maximum of 5 points. Likewise, the content validity (appropriateness as a teaching modality) obtained an average score of 4.8 of maximum 5 points. No differences were found between experts and novices concerning the recorded surgery completion times (p = 0.418) or the sizes of the lifted grafts (p = 0.110). During the evaluation of task performance, the expert surgeons (46.9 ± 3.7) were graded significantly better than the novices (36.4 ± 8.5), which proved the construct validity of the simulator (p = 0.001).

CONCLUSION

All investigated validities were confirmed and approved the simulator as a valid training tool for parietal graft lift.

Для цитирования: Hollensteiner Marianne, Malek Michael, Augat Peter, Fürst David, Schrödl Falk, Hunger Stefan, Esterer Benjamin, Gabauer Stefan, Schrempf Andreas. Validation of a simulator for cranial graft lift training: Face, content, and construct validity.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2018. DOI: 10.1016/j.jcms.2018.05.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.