Pulse-inversion US imaging of testicular ischemia: quantitative and qualitative analyses in a rabbit model.

Paltiel Harriet J, Kalish Leslie A, Susaeta Ricardo A, Frauscher Ferdinand, O'Kane Patrick L, Freitas-Filho Luiz G

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To quantitatively and qualitatively assess perfusion with pulse-inversion (PI) ultrasonography (US) in rabbit model of acute testicular ischemia.

MATERIALS AND

METHODS

Institutional animal care committee approval was obtained. After 35 rabbits underwent unilateral spermatic cord occlusion, testicular Doppler US and contrast material-enhanced PI imaging were performed. Enhancement data yielded perfusion measurements including mean value during the first 10 seconds, mean value over entire recorded replenishment curve, and curve slope during the first 5 seconds. Calculated perfusion ratios were compared with radiolabeled microsphere-derived perfusion ratios. Two readers assessed testicular perfusion as none, possible, or definite and relative perfusion as greater to the right testis than to the left, greater to the left testis than to the right, or as equal to both testes. With kappa statistics, interobserver agreement for all imaging methods was determined. Association between qualitative perfusion categories and radiolabeled microsphere-based perfusion measurements was assessed. Quantitative and qualitative determinations of relative perfusion were compared with radiolabeled microsphere-based measurements.

RESULTS

Correlations between calculated and radiolabeled microsphere-based perfusion ratios were determined (r=0.49-0.64). Interobserver agreement for presence of perfusion was excellent (kappa=0.76), and that for relative perfusion assessment was good (kappa=0.55). Neither kappa value varied significantly with imaging method. The percentage of times a testis classified as having definite perfusion had greater perfusion as measured with radiolabeled microspheres than a testis classified as having no perfusion or possible perfusion was higher with PI imaging than with Doppler US (85%-98% vs 72%-89%). Identification of the testis with less perfusion was better with quantitative methods than with qualitative assessment of images by the readers (75%-79% vs 34%-60%, P<.004).

CONCLUSION

PI imaging, compared with conventional Doppler US methods, provides superior assessment of perfusion in the setting of acute testicular ischemia.

Для цитирования: Paltiel Harriet J, Kalish Leslie A, Susaeta Ricardo A, Frauscher Ferdinand, O'Kane Patrick L, Freitas-Filho Luiz G. Pulse-inversion US imaging of testicular ischemia: quantitative and qualitative analyses in a rabbit model.. Radiology. 2006. DOI: 10.1148/radiol.2393050210.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.