MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.juro.2009.08.040

Медицинская библиотека · The Journal of urology · 2009

Ureteral metal stents: 10-year experience with malignant ureteral obstruction treatment.

Liatsikos Evangelos N, Karnabatidis Dimitrios, Katsanos Konstantinos, Kallidonis Panagiotis, Katsakiori Paraskevi, Kagadis George C, Christeas Nikolaos, Papathanassiou Zafiria, Perimenis Petros, Siablis Dimitrios

СтатьяОбзорПеревод пока не подготовлен

Аннотация

PURPOSE: Ureteral patency in malignant ureteral obstruction cases is a therapeutic challenge. We report our long-term experience with palliative treatment for extrinsic malignant ureteral obstruction with percutaneous placement of metal mesh stents.

MATERIALS AND

METHODS

From January 1996 to December 2005, 90 patients with a mean age of 59 years (range 35 to 80) with ureteral obstruction due to extrinsic ureteral compression and/or encasement by primary or metastatic tumors, or retroperitoneal lymphadenopathy underwent implantation of self-expandable metal mesh stents. A total of 119 ureters were managed. Followup included urinalysis, blood biochemistry tests and transabdominal ultrasound or intravenous urography.

RESULTS

The technical success rate of percutaneous antegrade insertion of ureteral self-expandable metal mesh stents was 100%. Renal biochemistry normalized and hydronephrosis gradually resolved 1 to 2 weeks after stent insertion. Median followup was 15 months (range 8 to 38). Hyperplastic reaction and/or encrustation, or tumor ingrowth developed in 45 stents. Secondary intervention, such as repeat balloon dilation and coaxial stenting, was done to improve patency. Migration was observed in 13 metal stents. The primary and secondary patency rates during followup were 51.2% and 62.1%, respectively. A double pigtail or external-internal stent was inserted in 45 cases in which secondary interventions did not ensure patency.

CONCLUSIONS

Internal drainage of extrinsic malignant ureteral obstruction with metal mesh stents provides long-term decompression of the upper urinary tract in select cases. Certain problems limit the application of metal mesh stents in the ureter. Further studies are warranted to identify independent predictors of ureteral patency after the application of metal stents for malignant obstruction.

Для цитирования: Liatsikos Evangelos N, Karnabatidis Dimitrios, Katsanos Konstantinos, Kallidonis Panagiotis, Katsakiori Paraskevi, Kagadis George C, Christeas Nikolaos, Papathanassiou Zafiria, Perimenis Petros, Siablis Dimitrios. Ureteral metal stents: 10-year experience with malignant ureteral obstruction treatment.. The Journal of urology. 2009. DOI: 10.1016/j.juro.2009.08.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.