MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aos.14310

Медицинская библиотека · Acta ophthalmologica · 2019

The tolerance of anisometropia.

Krarup Therese Grønhøj, Nisted Ivan, Christensen Ulrik, Kiilgaard Jens Folke, la Cour Morten

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: This study examines aniseikonia, Aniseikonia tolerance range (ATR), anisometropia and patient-reported outcomes (PRO) in an anisometropic population compared with a non-anisometropic population. The relationship between anisometropia and aniseikonia is determined, and the correlations between aniseikonia, anisometropia and ATR versus PRO are described.

METHODS

One hundred and twenty-three patients with IOL-induced anisometropia ≥1 dioptre (D) (the anisometropic group) and 17 patients who had IOL-induced anisometropia <1 D (the control group) were included. Best corrected visual acuity, aniseikonia, ATR and stereoacuity were examined, and two questionnaires were completed: convergence insufficiency symptom survey (CISS) and Visual Function Questionnaire (VFQ-39).

RESULTS

One hundred and thirteen patients had anisometropia >1 and <3 D, and 10 patients had anisometropia >3 D. There was no difference in PRO between the control group and the anisometropic group (Mann-Whitney, p-values VFQ: 0.96, CISS: 0.06). There was no correlation between anisometropia and PRO (Spearman's rank correlation test p-values: VFQ: 0.54, CISS: 0.57). Patients with low ATR were more sensitive towards anisometropia and had lower PRO than patients with high ATR (Mann-Whitney, p-values: VFQ: 0.0008, CISS: 0.11). A large tolerance of aniseikonia was observed.

CONCLUSION

No correlation between PRO and anisometropia or aniseikonia was found. Patients with low ATR are at risk of visual complaints if they are exposed to IOL-induced anisometropia. ATR might be a future screening tool in cataract patients.

Для цитирования: Krarup Therese Grønhøj, Nisted Ivan, Christensen Ulrik, Kiilgaard Jens Folke, la Cour Morten. The tolerance of anisometropia.. Acta ophthalmologica. 2019. DOI: 10.1111/aos.14310.