m+Medelevator.RU
← Поиск публикаций
Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique · 2012

[Assessment of movements of the different anatomic portions of the bladder, implications for image-guided radiation therapy for bladder cancer].

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pan Q, Thariat J, Bogalhas F, Lagrange J-L

Аннотация

PURPOSE: To assess interfraction and intrafraction bladder wall movements in the different anatomic portions of the bladder.

PATIENTS AND METHODS: Six patients were treated for prostate cancer with conformal irradiation. Daily online cone beam computed tomography was performed for repositioning and an additional one was performed following irradiation once weekly. Four craniocaudal levels were defined to calculate movements amplitudes compared to the scanner tracking: level 1 at the bladder neck, level 2 at mid-height of the bladder, level 3 at mid-height of the dome, level 4 at the apex in a distended bladder. Bladder height was also measured.

RESULTS: On 198 daily cone beam computed tomographies, radial bladder right/left/anterior/posterior wall displacements at level 2 were 0.08 ± 0.24, 0.11 ± 0.33, 0.16 ± 0.45 and 0.14 ± 0.50 cm and at level 3 0.07 ± 0.78, 0.18 ± 0.98, 0.43 ± 0.94 and 0.04 ± 1.02 cm. Dome and neck displacements were 0.08 ± 1.41 cm and 0.08 ± 0.64 cm. Seventeen cone beam computed tomographies were done following irradiation. Radial bladder right/left/anterior/halfway up the trine wall displacements at level 2 before and after irradiation were 0.02±0.18, 0.01±0.30, 0.09 ± 0.32 and 0.22 ± 0.42 cm and at level 3 0.27 ± 0.60, 0.37 ± 1.15, 0.18 ± 0.87 and 0.54 ± 1.68 cm.

CONCLUSION: Significant bladder wall displacements were observed on the anterior wall and upper portion of the bladder. Isotropic margins may not be sufficient to account for inter- and intrafraction bladder wall displacements at the latter levels. Tailored bladder anatomy-based anisotropic margins may be necessary to optimally spare the small intestine and to guaranty proper tumour coverage in case of bladder cancer. For upper bladder tumours, margins of over 2 cm would be necessary, which make them less adequate for external beam irradiation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты