MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s641270

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2026

Preoperative Corneal Astigmatic Direction is Associated with Stromal Mechanical Anisotropy in SMILE-Derived Lenticules.

Han Pengfei, Chen Peng, Fang Xiaolong, Qin Hongwei, Wu Yuan, Chen Shuangshuang, Li Yan, Zhang Jie, Zhou Qizhi

СтатьяПеревод в очереди

Аннотация

PURPOSE: Direction-dependent mechanical behavior exists in the human corneal stroma, but fixed-axis biomechanical testing may be influenced by preoperative astigmatic direction. This study evaluated whether corneal astigmatic direction, a routinely measurable clinical phenotype, corresponds to superior-inferior (SI) vs nasal-temporal (NT) mechanical anisotropy in human stromal lenticules obtained during small-incision lenticule extraction (SMILE).

PATIENTS AND

METHODS

Fifty-three spherical stromal lenticules with a programmed cylinder correction of 0 diopters were prospectively collected. Preoperative anterior corneal astigmatism was classified as with-the-rule (WTR) or against-the-rule (ATR), and the steep-axis information was decomposed into a vertical-horizontal component matched to the SI-NT mechanical testing coordinates. Equibiaxial testing was performed along the SI and NT axes, and tangent moduli were calculated at 0.03 MPa. The signed meridional difference index (MDI) was defined as ESI - ENT.

RESULTS

WTR lenticules predominantly showed higher SI modulus, whereas ATR lenticules predominantly showed higher NT modulus. The vertical-horizontal astigmatic component was strongly correlated with signed MDI (Spearman rho = 0.875, P < 0.001), and this association remained significant after multivariable adjustment (β = 0.673 MPa/diopter, 95% CI 0.537-0.809, P < 0.001). Corneal astigmatism magnitude was also associated with direction-independent anisotropy magnitude.

CONCLUSION

Preoperative corneal astigmatic direction may be a clinically measurable stratification variable for interpreting fixed-axis stromal mechanical anisotropy measurements in SMILE-derived lenticules. These findings support incorporating directional clinical phenotypes into corneal biomechanical research and patient-specific modeling, while requiring validation in larger independent samples.

Для цитирования: Han Pengfei, Chen Peng, Fang Xiaolong, Qin Hongwei, Wu Yuan, Chen Shuangshuang, Li Yan, Zhang Jie, Zhou Qizhi. Preoperative Corneal Astigmatic Direction is Associated with Stromal Mechanical Anisotropy in SMILE-Derived Lenticules.. Clinical ophthalmology (Auckland, N.Z.). 2026. DOI: 10.2147/opth.s641270.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.