MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/lap.2017.0032

Медицинская библиотека · Journal of laparoendoscopic & advanced surgical techniques. Part A · 2017

Endoscopic Ultrasound-Guided Direct Portal Pressure Measurement Using a Digital Pressure Wire with Real-Time Remote Display: A Survival Study.

Schulman Allison R, Thompson Christopher C, Ryou Marvin

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Portal hypertension is necessary for the development of most clinical complications of cirrhosis. We recently reported a novel, endoscopic ultrasound (EUS)-guided technique for direct portal pressure measurements using a digital pressure wire.

AIMS: The aims of this study were to (1) evaluate safety in an animal survival model and (2) compare direct portal vein (PV) versus transhepatic access of a first-order venule.

MATERIALS AND

METHODS

Yorkshire pigs, weighing 40-55 kg. Procedures were performed under general anesthesia. PV was identified using a linear array echoendoscope and accessed with a 22-G fine needle aspiration needle preloaded with a digital pressure wire. Access was confirmed by portal venography. Mean digital pressure measurements were recorded over 30 seconds, and again after accessing a first-order portal venule in a transhepatic manner. Procedure times and video logs were maintained throughout. Animals were survived for 2 weeks. Repeat portal pressure measurements were performed before euthanasia and necropsy.

RESULTS

EUS-guided portal pressure measurements ranged from 3 to 11 mm Hg (mean 6.1) and were performed in a mean time of 214 seconds. There was no difference in measurement between the PV and first-order venule, or between baseline and 2-week follow-up. Five of 5 animals survived without incident. On necropsy, there was no evidence of thrombus or hemorrhage.

CONCLUSIONS

This study represents the first survival study after EUS-guided direct portal pressure measurements using a digital pressure wire. This method appears safe, straightforward, and precise. Measurements of the PV and a first-order portal venule appear equivalent, and serial measurement seems feasible.

Для цитирования: Schulman Allison R, Thompson Christopher C, Ryou Marvin. Endoscopic Ultrasound-Guided Direct Portal Pressure Measurement Using a Digital Pressure Wire with Real-Time Remote Display: A Survival Study.. Journal of laparoendoscopic & advanced surgical techniques. Part A. 2017. DOI: 10.1089/lap.2017.0032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.