Acta radiologica (Stockholm, Sweden : 1987) · 2017
Impact of transjugular intrahepatic portosystemic shunt implantation on liver perfusion measured by volume perfusion CT.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Preibsch Heike, Spira Daniel, Thaiss Wolfgang M, Syha Roland, Nikolaou Konstantin, Ketelsen Dominik, Lauer Ulrich M, Horger Marius
Аннотация
Background Implantation of a transjugular intrahepatic portosystemic shunt (TIPS) induces changes of liver perfusion. Purpose To determine the changes in arterial, portal venous, and total perfusion of the liver parenchyma induced by TIPS using the technique of volume perfusion computed tomography (VPCT) and compare results with invasively measured hepatic intravascular pressure values. Material and Methods VPCT quantification of liver perfusion was performed in 23 patients (mean age, 62.5 ± 8.8 years) with portal hypertension in the pre-TIPS and post-TIPS setting, respectively. A commercially available software package was used for post-processing, enabling separate calculation of the dual (arterial [ALP] and portal venous [PVP]) blood supply and additionally of the hepatic perfusion index (HPI) (HPI = ALP/(ALP + PVP)*100%). Invasive pressure measurements were performed during the intervention, before and after TIPS placement. Liver function tests performed before and after the procedure were compared. Results Mean decrease of pressure gradient through TIPS was 13.3 mmHg. Mean normal values for ALP, PVP, and total perfusion (ALP + PVP) before TIPS were 15.9, 37.7, and 53.5 mL/100 mL/min, respectively, mean HPI was 35.4%. After TIPS, ALP increased to a mean value of 37.7 mL/100 mL/min, PVP decreased (15.7 mL/100 mL/min, P < 0.05), whereas total perfusion remained unchanged (53.4 mL/100 mL/min, P = 0.97). HPI increased (71.9%; P < 0.05). No correlation between invasive pressure measurement and VPCT parameters was observed. After TIPS, liver function tests were found to worsen with a significant increase of bilirubin ( P < 0.05). Conclusion Following TIPS placement, ALP and HPI increased in all patients, whereas PVP markedly decreased. Interestingly, the magnitude of decrease in portosystemic pressure gradients was not found to correlate with VPCT parameters.