MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mri.2024.04.013

Медицинская библиотека · Magnetic resonance imaging · 2024

DeepFLAIR: A neural network approach to mitigate signal and contrast loss in temporal lobes at 7 Tesla FLAIR images.

Uher Daniel, Drenthen Gerhard S, Poser Benedikt A, Hofman Paul A M, Wagner Louis G, van Lanen Rick H G J, Hoeberigs Christianne M, Colon Albert J, Schijns Olaf E M G, Jansen Jacobus F A, Backes Walter H

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Higher magnetic field strength introduces stronger magnetic field inhomogeneities in the brain, especially within temporal lobes, leading to image artifacts. Particularly, T2-weighted fluid-attenuated inversion recovery (FLAIR) images can be affected by these artifacts. Here, we aimed to improve the FLAIR image quality in temporal lobe regions through image processing of multiple contrast images via machine learning using a neural network.

METHODS

Thirteen drug-resistant MR-negative epilepsy patients (age 29.2 ± 9.4y, 5 females) were scanned on a 7 T MRI scanner. Magnetization-prepared (MP2RAGE) and saturation-prepared with 2 rapid gradient echoes, multi-echo gradient echo with four echo times, and the FLAIR sequence were acquired. A voxel-wise neural network was trained on extratemporal-lobe voxels from the acquired structural scans to generate a new FLAIR-like image (i.e., deepFLAIR) with reduced temporal lobe inhomogeneities. The deepFLAIR was evaluated in temporal lobes through signal-to-noise (SNR), contrast-to-noise (CNR) ratio, the sharpness of the gray-white matter boundary and joint-histogram analysis. Saliency mapping demonstrated the importance of each input image per voxel.

RESULTS

SNR and CNR in both gray and white matter were significantly increased (p < 0.05) in the deepFLAIR's temporal ROIs, compared to the FLAIR. The gray-white matter boundary sharpness was either preserved or improved in 10/13 right-sided temporal regions and was found significantly increased in the ROIs. Multiple image contrasts were influential for the deepFLAIR reconstruction with the MP2RAGE second inversion image being the most important.

CONCLUSIONS

The deepFLAIR network showed promise to restore the FLAIR signal and reduce contrast attenuation in temporal lobe areas. This may yield a valuable tool, especially when artifact-free FLAIR images are not available.

Для цитирования: Uher Daniel, Drenthen Gerhard S, Poser Benedikt A, Hofman Paul A M, Wagner Louis G, van Lanen Rick H G J, Hoeberigs Christianne M, Colon Albert J, Schijns Olaf E M G, Jansen Jacobus F A, Backes Walter H. DeepFLAIR: A neural network approach to mitigate signal and contrast loss in temporal lobes at 7 Tesla FLAIR images.. Magnetic resonance imaging. 2024. DOI: 10.1016/j.mri.2024.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление