m+Medelevator.RU
← Поиск публикаций
BMC oral health · 2024

Biomechanical behaviour of tilted abutment after fixed partial denture restoration of CAD/CAM materials.

СтатьяКлинический случайНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhu Tong, Chen Jingyi, Xu Yichen, Zhu Zhou, Wang Jian, Pei Xibo, Qiao Mingxin, Cheng Bin, Li Ruyi, Wan Qianbing

Аннотация

BACKGROUND: Failure to restore missing teeth in time can easily lead to the mesial tilting of the distal abutment teeth. However, a fixed partial denture (FPD) can improve stress conduction and distribution and prevent periodontal injuries. In these more complex cases, it is necessary to consider various factors comprehensively to improve conventional treatment planning and achieve better results.

METHODS: We selected a patient with a missing first molar and a mesial inclination of the second molar, leaving inadequate space or bone mass for implant denture restoration, necessitating an FPD for restoration. Three-dimensional finite element analysis (3D-FEA) combined with photoelastic analysis were used to explore how the inclination angle (0 ‒ 30°) and different dental restoration materials (zirconia, lithium disilicate, polymer-infiltrated ceramic network, and resin composite) affect the biomechanical behaviour of FPD‒abutments‒periodontal tissue complex.

RESULTS: The stress was easily concentrated in the FPD connectors, enamel shoulder collar, periapical area, and root bifurcation. The stress on FPD and the periodontal ligament (PDL) of the second premolar increased with an increase in the elastic modulus of FPD, with an opposite trend in the abutments, the alveolar bone, and the PDL of the second molar. The stress on the FPD and alveolar bone increased with increased inclination angle of the distal abutment. The stress on two abutments and their PDL were positively correlated with the inclination angle in two stages; however, when the inclination angle > 12°, the second premolar and its PDL showed a negative correlation.

CONCLUSIONS: FPDs can be used for restoration within 24° of distal abutment inclination, but protecting the abutments (< 12° especially) and the periodontal tissue (> 12° especially) must be taken seriously. For this purpose, an FPD material with higher strength is recommended.