DOI 10.1007/s00330-021-08324-8
Diagnostic performance of diffusion-weighted MR neurography as an adjunct to conventional MRI for the assessment of brachial plexus pathology.
Аннотация
OBJECTIVE
To investigate the diagnostic performance of diffusion-weighted (DW) MR neurography as an adjunct to conventional MRI for the assessment of brachial plexus pathology.
METHODS
DW MR neurography scans (short tau inversion recovery fat suppression and b-value of 800 s/mm2) of 15 consecutive patients with and 45 randomly selected patients without brachial plexus abnormalities were independently and blindly reviewed by a 5th year radiology resident, a junior neuroradiologist, and a senior neuroradiologist.
RESULTS
Median interpretation times ranged between 20 and 30 s. Interobserver agreement was substantial (κ coefficients of 0.715-0.739). For the 5th year radiology resident, sensitivity was 53.3% (95% CI, 30.1-75.2%) and specificity was 100% (95% CI, 92.1-100%). For the junior neuroradiologist, sensitivity was 66.7% (95% CI, 41.7-84.8%) and specificity was 100% (95% CI, 92.1-100%). For the senior neuroradiologist, sensitivity was 73.3% (95% CI, 48.1-89.1%) and specificity was 95.6% (95% CI, 85.2-98.8%). Traumatic injury, metastases, radiation-induced plexopathy, schwannoma, and inflammatory process of unknown cause could be detected by the majority of readers (100% detection rate for each disease entity by at least two readers). Neuralgic amyotrophy, iatrogenic injury after first rib resection, and cervical disc herniation causing root compression were not detected by the majority of readers (0% detection rate for each disease entity by at least two readers).
CONCLUSION
DW MR neurography may be a useful adjunct when assessing for brachial plexus abnormalities, because interpretation time is relatively short and the majority of abnormalities can be detected.
KEY POINTS: • DW MR neurography interpretation time of the brachial plexus is relatively short (median interpretation times of 20 to 30 s). • Interobserver agreement between three readers with different levels of experience is substantial (κ coefficients of 0.715 to 0.739). • DW MR neurography can detect brachial plexus abnormalities with moderate sensitivity (53.3 to 73.3%) and high specificity (95.6 to 100%).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.