MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00016489.2012.744143

Медицинская библиотека · Acta oto-laryngologica · 2012

Superparamagnetic iron oxide-enhanced interstitial magnetic resonance lymphography to detect a sentinel lymph node in tongue cancer patients.

Mizokami Daisuke, Kosuda Shigeru, Tomifuji Masayuki, Araki Koji, Yamashita Taku, Shinmoto Hiroshi, Shiotani Akihiro

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

CONCLUSION

This is the first report on human sentinel node (SN) detection by interstitial magnetic resonance (MR) lymphography with superparamagnetic iron oxide (SPIO) in tongue cancer patients who also underwent lymphoscintigraphy. Our results indicate that further studies are warranted, as this novel method may replace current scintigraphic techniques.

OBJECTIVES

To examine the feasibility of interstitial MR lymphography using SPIO for SN detection in the head and neck region.

METHODS

MR images were acquired sequentially at 10 min, 30 min, and 24 h after submucosally injecting 0.1 ml SPIO (ferucarbotran) around the tumor in three patients with tongue cancer without cervical lymph node metastasis (clinical T2N0M0).

RESULTS

The SNs were clearly visualized in the 10 min interstitial MR lymphography images and were completely concordant with those visualized by (99m)Tc-radiocolloid lymphoscintigraphy and a gamma probe in all cases. Iron incorporation into the SNs was confirmed by pathological examination.

Для цитирования: Mizokami Daisuke, Kosuda Shigeru, Tomifuji Masayuki, Araki Koji, Yamashita Taku, Shinmoto Hiroshi, Shiotani Akihiro. Superparamagnetic iron oxide-enhanced interstitial magnetic resonance lymphography to detect a sentinel lymph node in tongue cancer patients.. Acta oto-laryngologica. 2012. DOI: 10.3109/00016489.2012.744143.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.