Feasibility of pneumoperitoneum diagnosis using point-of-care ultrasound: a pilot study using a fresh cadaver model.

Herbst Meghan Kelly, Carter Elizabeth M, Wu Shirley, Dietrich Christoph Frank, Hoffmann Beatrice

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To assess the accuracy of point-of-care ultrasound (PoCUS) in the hands of two trained and blinded emergency physicians (EPs) in detecting very small amounts of free intraperitoneal air injected intra-abdominally, using a fresh human cadaver model.

MATERIAL AND

METHODS

Fifteen cadavers were injected on 3 occasions with predefined quantities of free intraperitoneal air ranging from 0-10 mL. Seven cadavers were injected in the mid-epigastrium (ME), while 8 were injected in the left lower quadrant (LLQ). Each cadaver was scanned after each of the 3 injections by 2 trained and blinded EPs, resulting in 45 scans per sonographer. Scans were performed using previously validated and standardized techniques. All scans were recorded, time-stamped and labeled. For each scan the sonographers indicated "yes" or "no" to whether pneumoperitoneum was detected. A chi square analysis was performed to determine the sensitivity and specificity of PoCUS utilized by each sonographer of pneumoperitoneum based on the location and volume of air injected.

RESULTS

Free air (0.25-10 mL) injected into the ME was successfully diagnosed in 36/42 instances (86% sensitivity), but only detected in 10/36 instances when injected into the LLQ (28% sensitivity). Both EPs detected all air injections of ≥2 mL into the ME.

CONCLUSION

Detection of free air originating from the midepigastric region may become a future PoCUS indication for adequately trained EPs.

Для цитирования: Herbst Meghan Kelly, Carter Elizabeth M, Wu Shirley, Dietrich Christoph Frank, Hoffmann Beatrice. Feasibility of pneumoperitoneum diagnosis using point-of-care ultrasound: a pilot study using a fresh cadaver model.. Medical ultrasonography. 2021. DOI: 10.11152/mu-3238.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.