MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1443-1661.2012.01260.x

Медицинская библиотека · Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2012

Use of a partially covered self-expandable metallic stent to treat a biliary stricture secondary to chronic pancreatitis complicated by recurrent cholangitis: a case report.

Okabe Yoshinobu, Ishida Yusuke, Sasaki Yu, Ushijima Tomoyuki, Sugiyama Gen, Tsuruta Osamu

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

The patient was a 69 year old man who had been diagnosed with alcoholic chronic pancreatitis and lower common bile duct (CBD) stricture. He subsequently developed cholangitis 2-3 times a year, and we replaced the endoscopic biliary stent (EBS) each time. In April 2010, he was admitted because of complication by a liver abscess and acute cholangitis. We performed percutaneous transhepatic liver abscess drainage. The inflammatory findings then rapidly improved, but the patient developed acute cholangitis due to the sludge and the stones. Then, we placed a partially covered self-expandable metallic stent (C-SEMS) in the lower CBD and performed endoscopic lithotripsy through the C-SEMS, and the cholangitis subsequently improved. Two weeks after, we removed the C-SEMS endoscopically and replaced it with a 10 Fr plastic stent; since then there have been no recurrences of cholangitis. Our experience in this case suggested that when a plastic stent is placed long-term to treat a biliary stricture associated with chronic pancreatitis, it might be useful to also control biliary sludge and stones using a C-SEMS.

Для цитирования: Okabe Yoshinobu, Ishida Yusuke, Sasaki Yu, Ushijima Tomoyuki, Sugiyama Gen, Tsuruta Osamu. Use of a partially covered self-expandable metallic stent to treat a biliary stricture secondary to chronic pancreatitis complicated by recurrent cholangitis: a case report.. Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society. 2012. DOI: 10.1111/j.1443-1661.2012.01260.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.