MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/bmt-2024-0620

Медицинская библиотека · Biomedizinische Technik. Biomedical engineering · 2025

Machine learning prediction of effective radiation doses in various computed tomography applications: a virtual human phantom study.

Tanyildizi-Kokkulunk Handan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

In this work, it was aimed to employ machine learning (ML) algorithms to accurately forecast the radiation doses for phantoms while accounting for the most popular CT protocols.

METHODS

A cloud-based software was utilized to calculate the effective doses from different CT protocols. To simulate a range of adult patients with different weights, eight entire body mesh-based computational phantom sets were used. The head, neck, and chest-abdomen-pelvis CT scan characteristics were combined to create a dataset with 33 rows for each phantom and 792 rows total. At the ML stage, linear (LR), random forest (RF) and support vector regression (SVR) were used. Mean absolute error, mean squared error and accuracy were used to evaluate the performances.

RESULTS

The female phantoms received higher doses (7.8 %) than males. Furthermore, an average of 11 % more dose was taken to the normal weight phantom than to the overweight, the overweight in comparison to the obese I, and the obese I in comparison to the obese II. Among the ML algorithms, the LR showed 0 error rate and 100 % accuracy in predicting CT doses.

CONCLUSIONS

The LR was shown to be the best approach out of those used in the ML estimation of CT-induced doses.

Для цитирования: Tanyildizi-Kokkulunk Handan. Machine learning prediction of effective radiation doses in various computed tomography applications: a virtual human phantom study.. Biomedizinische Technik. Biomedical engineering. 2025. DOI: 10.1515/bmt-2024-0620.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление