MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/030089161309900205

Медицинская библиотека · Tumori · 2013

Sentinel lymph node biopsy in breast cancer: review on various methodological approaches.

Zengel Baha, Yararbas Ulkem, Sirinocak Ahmet, Ozkok Guliz, Denecli Ali Galip, Postaci Hakan, Uslu Adam

СтатьяПеревод пока не подготовлен

Аннотация

AIMS AND

BACKGROUND

Sentinel lymph node biopsy has been accepted as a standard procedure for early stage breast cancer. In this retrospective analysis, the results obtained with different methodological approaches using radiocolloid with or without blue dye were examined.

METHODS

A total of 158 sentinel lymph node biopsies were performed in 152 patients. Group A (85 patients) underwent lymphatic mapping using a combination of periareolar intradermal radiocolloid and subareolar blue dye injections. Group B (73 patients) underwent only periareolar intradermal radiocolloid injection. One large tin colloid and two small radiocolloids (nanocolloid of serum albumin -NC- and colloidal rhenium sulphide -CS-) were used.

RESULTS

Successful lymphatic mapping was attained in 157 of 158 procedures (99.4%). Radiocolloids localized sentinel lymph nodes in 99.4% and blue dye in 75.3% of the cases. The number of sentinel lymph nodes removed was greater in nanocolloid and colloidal rhenium sulphide groups (P ≤0.05). Among 60 metastatic sentinel lymph nodes, frozen section analysis using hematoxylin and eosin staining failed to detect 1 macro- and 10 micrometastasis. Radiocolloid uptake was higher in sentinel lymph nodes accumulating blue dye (1643 ± 3216 counts/10 sec vs 526 ± 1284 counts/10 sec, P <0.001). Higher count rates were obtained by using larger sized colloids (median and interquartile range: tin colloid, 2050 and 4548; nanocolloid, 835 and 1799; colloidal rhenium sulphide, 996 and 2079; P = 0.01). Only 2 extra-axillary sentinel lymph nodes were visualized using periareolar intradermal injection modality.

CONCLUSIONS

Radiocolloids were more successful than blue dye in sentinel lymph node detection. More sentinel lymph nodes were harvested with small colloids, but different sized radiocolloids were similarly successful. Sentinel lymph nodes having higher radiocolloid uptake tended to accumulate blue dye more frequently. Sentinel lymph nodes manifested higher count rates when a larger colloid was used. Frozen section was very successful in detecting macrometastatic disease in sentinel lymph nodes, but the technique failed in most of the micrometastates.

Для цитирования: Zengel Baha, Yararbas Ulkem, Sirinocak Ahmet, Ozkok Guliz, Denecli Ali Galip, Postaci Hakan, Uslu Adam. Sentinel lymph node biopsy in breast cancer: review on various methodological approaches.. Tumori. 2013. DOI: 10.1177/030089161309900205.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.