MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/annonc/mdt151

Медицинская библиотека · Annals of oncology : official journal of the European Society for Medical Oncology · 2013

The standard tangential fields used for breast irradiation do not allow optimal coverage and dose distribution in axillary levels I-II and the sentinel node area.

Belkacemi Y, Allab-Pan Q, Bigorie V, Khodari W, Beaussart P, Totobenazara J-L, Mège J-P, Caillet P, Pigneur F, Dao T-H, Salmon R, Calitchi E, Bosc R

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Recent data from ACOSOG Z0011 and NSABP B32 trials suggested no need for axillary lymph node dissection (ALND) in patients with micrometastatic involvement of the sentinel lymph node (SLN). The low rate of axillary recurrence was attributed to the axilla coverage by the tangential fields (TgFs) irradiation and systemic therapy. This study aimed to evaluate dose distribution and coverage of the axilla levels I-II and the SLN area.

PATIENTS AND

METHODS

One hundred and nine patients were analyzed according to three groups: group 1 (50 Gy; n = 18), group 2 (60 Gy; n = 34) and group 3 (66 Gy; n = 57). Patients were treated using the standard (STgF; n = 22) or high (HTgF; n = 87) TgF.

RESULTS

The median doses delivered to level I using HTgF versus STgF were 33 and 20 Gy (P = 0.0001). The mean dose delivered to the SLN area was only 28 Gy. Additionally, the SLN area was totally included in the HTgF in 1 out of 12 patients who had intraoperative clip placement in the SNL area.

CONCLUSIONS

TgFs provide a limited coverage of the axilla and the SNLB area. This information should be considered when only TgFs are planned to target the axilla in patients with a positive SLN without ALND. Standardization of locoregional radiotherapy in this situation is urgently needed.

Для цитирования: Belkacemi Y, Allab-Pan Q, Bigorie V, Khodari W, Beaussart P, Totobenazara J-L, Mège J-P, Caillet P, Pigneur F, Dao T-H, Salmon R, Calitchi E, Bosc R. The standard tangential fields used for breast irradiation do not allow optimal coverage and dose distribution in axillary levels I-II and the sentinel node area.. Annals of oncology : official journal of the European Society for Medical Oncology. 2013. DOI: 10.1093/annonc/mdt151.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.