Application of contrast enhanced ultrasound in gallbladder lesion: is it helpful to improve the diagnostic capabilities?
Аннотация
UNLABELLED: The aim of this study is to evaluate if contrast enhanced ultrasound (CEUS) can improve the differential diagnostic performance of gallbladder (GB) lesions.
MATERIALS AND
METHODS
Forty-nine patients (18 men, 31 women; mean age, 54.8±14.4 years, range age, 22-78 years) with GB lesions (mass-forming and wall-thickened types) were enrolled in this study. All patients underwent conventional ultrasonography (US) and CEUS examination. The imaging characteristics of GB lesions were analyzed to compare the diagnostic performance of US and CEUS. The final diagnosis was obtained by histopathology.
RESULTS
There were significant differences between benign and malignant GB lesions with regards to size, shape, vascularity, the integrity and margin of GB wall and time to iso-enhancement on CEUS (p<0.05). However, no significant difference was found concerning the enhancement patterns between the two groups (p>0.05). Logistic regression analysis showed that the boundary between liver and GB wall (p=0.017) and vascularity on color Doppler flow imaging (p=0.013) were two independent predictors of malignancy. The diagnostic accuracy of US could be improved in combination with CEUS (65.3% vs 83.7%). The diagnostic accuracy of the GB wall thickening type was higher than the mass forming type.
CONCLUSION
CEUS could improve the diagnostic performance of GB lesions, especially for wall-thickened type lesions.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.