MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3413/nukmed-0277

Медицинская библиотека · Nuklearmedizin. Nuclear medicine · 2010

Prediction of lymph node metastases in NSCLC. Three dimensional anatomical parameters do not substitute FDG-PET-CT.

Beyer F, Buerke B, Gerss J, Scheffe K, Puesken M, Weckesser M, Schober O, Heindel W, Wessling J

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To distinguish between benign and malignant mediastinal lymph nodes in patients with NSCLC by comparing 2D and semi-automated 3D measurements in FDG-PET-CT.

PATIENTS, MATERIAL,

METHODS

FDG-PET-CT was performed in 46 patients prior to therapy. 299 mediastinal lymph-nodes were evaluated independently by two radiologists, both manually and by semi-automatic segmentation software. Longest-axial-diameter (LAD), shortest-axial-diameter (SAD), maximal-3D-diameter, elongation and volume were obtained. FDG-PET-CT and clinical/FDG-PET-CT follow up examinations and/or histology served as the reference standard. Statistical analysis encompassed intra-class-correlation-coefficients and receiver-operator-characteristics-curves (ROC).

RESULTS

The standard of reference revealed involvement in 87 (29%) of 299 lymph nodes. Manually and semi-automatically measured 2D parameters (LAD and SAD) showed a good correlation with mean intraclass coefficients of .80 and .72, respectively. Semi-automated prediction revealed the highest areas-under-the-ROC-curve for volume (.75, 95%CI: .69-81) and SAD (.75, 95%CI: .70-.81). AUC for LAD and maximal-3D diameter were about .68. Substantially lower accuracies were found for elongation (.57, 95%CI: .50-.64).

CONCLUSION

Optimized semi-automated three dimensional parameters by CT cannot approximate reported data on FDG-PET-CT for lymph node assessment in NSCLC. SAD remains the most accurate and at the same time simple to achieve anatomical criterion for definition of NSCLC target lesions.

Для цитирования: Beyer F, Buerke B, Gerss J, Scheffe K, Puesken M, Weckesser M, Schober O, Heindel W, Wessling J. Prediction of lymph node metastases in NSCLC. Three dimensional anatomical parameters do not substitute FDG-PET-CT.. Nuklearmedizin. Nuclear medicine. 2010. DOI: 10.3413/nukmed-0277.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.