PURPOSE: To evaluate the predictive value of computed tomography (CT) scanning and single-photon emission computed tomography (SPECT) gallium (Ga) scanning in the disease-free survival of patients receiving high-dose chemotherapy and autologous stem-cell transplantation for non-Hodgkin's lymphoma (NHL).

PATIENTS AND

METHODS

One hundred forty-three patients undergoing transplant for NHL underwent CT scanning of chest, abdomen, and pelvis, and a SPECT Ga scan before transplantation and at day + 100 after transplant. The failure-free survival (FFS) by scan result was analyzed.

RESULTS

In the diffuse aggressive lymphoma patients, the 1-year FFS for patients having a positive SPECT Ga scan at day + 100 was 15% compared with a 3-year FFS of 47% for those with a negative scan (P < .001). Patients with a positive CT scan at day + 100 had a 36% 3-year FFS, and those with a negative CT scan had a 39% 3-year FFS (P = not significant [NS]). An analysis of the combination of CT scan and SPECT Ga scan results at day + 100 posttransplant demonstrated a 3-year FFS of 14% if they were both abnormal; if the CT was positive and Ga was negative, the 3-year FFS was 68%; positive Ga with a negative CT was 25%; and both negative was 34% (P = .0015). For the patients with follicular NHL, those with a positive SPECT Ga at day + 100 had a 14% 1-year FFS compared with those with a negative scan, who had a 45% 3-year FFS (P < .001). In the follicular NHL patients, the 3-year FFS of those with a positive CT was 17% compared with a 64% 3-year FFS for patients with a negative CT scan (P < .001).

CONCLUSION

The use of SPECT Ga scan at day + 100 posttransplant for evaluation of disease activity in patients with diffuse aggressive NHL was highly predictive of eventual outcome and was more predictive than the CT scan results. However, for patients with follicular NHL, the addition of SPECT Ga scanning to CT scanning did not add substantially to the evaluation of transplant outcome.

Для цитирования: Vose J M, Bierman P J, Anderson J R, Harrison K A, Dalrymple G V, Byar K, Kessinger A, Armitage J O. Single-photon emission computed tomography gallium imaging versus computed tomography: predictive value in patients undergoing high-dose chemotherapy and autologous stem-cell transplantation for non-Hodgkin's lymphoma.. Journal of clinical oncology : official journal of the American Society of Clinical Oncology. 1996. DOI: 10.1200/jco.1996.14.9.2473.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.