MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jim.2009.11.019

Медицинская библиотека · Journal of immunological methods · 2009

Ethylene-Diamine-Tetra-Acetate (EDTA) mimics the effect of regulatory T cells in suppression assays: a potential pitfall when using AutoMACS-separated cells.

Dige Anders, Hvas Christian Lodberg, Kelsen Jens, Deleuran Bent, Dahlerup Jens F, Agnholt Jørgen

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

CD4+CD25+ regulatory T cells (Tregs) mediate tolerance towards self antigens and prevent the development of autoimmunity. Treg function is typically evaluated by the ability to suppress proliferation and cytokine production of co-cultured CD4+CD25- T cells in Treg suppression assays. Purified Tregs are often obtained using the "Regulatory T Cell isolation kit" from Miltenyi Biotech. Separation can be performed manually using single columns or automated using the AutoMACS Cell Separator. In this Technical Note we present a serious pitfall in Treg suppression assays when evaluating magnetically separated CD4+CD25+ T cells obtained by the "Regulatory T Cell isolation kit" and AutoMACS Cell Separator. The AutoMACS Running Buffer recommended by the manufacturer for separation contains Ethylene-Diamine-Tetra-Acetate (EDTA). Here we show that even minute traces of EDTA in the CD4+CD25+ T cell fraction mediate significant suppression of CD4+CD25- T cell proliferation. The suppressive effect of EDTA is dose-dependent and mimics Treg mediated suppression of CD4+CD25- T cell proliferation. The influence of EDTA can be eliminated by thorough washing of the CD4+CD25+ T cell fraction following the separation. Our observation may have implications for other cell separation methods using EDTA-containing buffers.

Для цитирования: Dige Anders, Hvas Christian Lodberg, Kelsen Jens, Deleuran Bent, Dahlerup Jens F, Agnholt Jørgen. Ethylene-Diamine-Tetra-Acetate (EDTA) mimics the effect of regulatory T cells in suppression assays: a potential pitfall when using AutoMACS-separated cells.. Journal of immunological methods. 2009. DOI: 10.1016/j.jim.2009.11.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.