MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jgh.12789

Медицинская библиотека · Journal of gastroenterology and hepatology · 2015

Assessment of liver fibrosis: the relationship between point shear wave elastography and quantitative histological analysis.

Ding Hong, Ma Jiao-jiao, Wang Wen-ping, Zeng Wen-jiao, Jiang Tao, Huang Bei-jian, Chen Shi-yao

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM: Traditional pathological scoring systems for liver fibrosis progression are predominantly based on the description of architectural changes with no consideration of the amount of collagen fiber deposition. Our purpose was to explore a true histological standard in accordance with the liver stiffness measured by point shear wave elastography (PSWE) in patients with chronic hepatitis B.

METHODS

A total of 78 patients with liver neoplasms underwent liver stiffness measurements with PSWE as well as biochemical investigations within 3 days before partial hepatectomy. One tissue section of the liver specimens was stained with HE trichrome and evaluated traditionally with the Scheuer scoring system. The other tissue section was stained with picroSirius red and was evaluated according to the semiquantitative Chevallier et al. scoring system. In addition, this second tissue section was evaluated for the collagen proportionate area (CPA) with computer-assisted digital image analysis. The reproducibility of PSWE technology was explored through the intra-class correlation coefficient of a reliability analysis.

RESULTS

The PSWE technology revealed good reproducibility in liver stiffness measurements, and the PSWE values increased with the pathological severity of liver fibrosis on both the Scheuer scoring system and the semiquantitative Chevallier et al. scoring system. PSWE values exhibited more reasonable relationships with CPA (r = 0.628, P = 0.00 < 0.05) than with the Scheuer scoring system (r = 0.473, P = 0.00 < 0.05) or the Chevallier et al. semiquantitative scoring system (r = 0.487, P = 0.00 < 0.05).

CONCLUSION

CPA is a better pathological parameter than traditional semiquantitative scoring systems in accordance with liver stiffness measured by PSWE technology.

Для цитирования: Ding Hong, Ma Jiao-jiao, Wang Wen-ping, Zeng Wen-jiao, Jiang Tao, Huang Bei-jian, Chen Shi-yao. Assessment of liver fibrosis: the relationship between point shear wave elastography and quantitative histological analysis.. Journal of gastroenterology and hepatology. 2015. DOI: 10.1111/jgh.12789.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.