MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua yi xue za zhi · 2013

[Values of magnetic resonance spectrum imaging in the diagnosis of hepatic fibrosis of rats].

Fan Guo-hua, Gong Jian-ping, Shen Jun-kang, Zhang Cai-yuan, Xu Xiao-qiu, Xu Liang, Yu Ze-yang, Zhang Wei, Wu Hao-rong

Аннотация на английскомСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To explore the values of magnetic resonance spectrum (MRS) in early diagnosis, quantization analysis and staging of hepatic fibrosis.

METHODS

A rat model of hepatic fibrosis was established by the method of carbon tetra carbon (CCl4). A total of 47 SD rats were divided into model (n = 40) and control (n = 7) groups. 1H-MRS was performed. The model rats of hepatic fibrosis were grouped according to their pathological stages. The ratio of peak height and peak area of metabolites and lipid (Cho/Lip, Glx/Lip, Lac/Lip and Cr/Lip) were calculated and compared respectively.

RESULTS

The ratios of peak height of metabolites and lipid were as follows: ratio of Cho and Lip: significant differences existed between control and grades 3 and 4 model groups (P < 0.05); ratio of Glx and Lip: significant differences existed between control and grades 2, 3 and 4 model groups (P < 0.05); ratio of Cr and Lip: significant differences existed between control and grade 3 model groups (P < 0.05). The peak area ratio of main metabolites and lipid of liver were as follows: ratio of Cho and Lip: significant differences existed between control and grade 4 model groups (P < 0.05); ratio of Glx and Lip: significant differences existed between control and other groups (P < 0.05); ratio of Cr and Lip: significant differences existed between control and grade 4 model groups (P < 0.05); ratio of Lac and Lip: no significant differences existed between these groups (P > 0.05).

CONCLUSION

The ratios of peak height and peak area of Cho/Lip, Glx/Lip and Cr/Lip are important for the staging of hepatic fibrosis.

Для цитирования: Fan Guo-hua, Gong Jian-ping, Shen Jun-kang, Zhang Cai-yuan, Xu Xiao-qiu, Xu Liang, Yu Ze-yang, Zhang Wei, Wu Hao-rong. [Values of magnetic resonance spectrum imaging in the diagnosis of hepatic fibrosis of rats].. Zhonghua yi xue za zhi. 2013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.