m+Medelevator.RU
← Поиск публикаций
Academic radiology · 2025

Impact of Endorectal Coil Use on Extraprostatic Extension Detection in Prostate MRI: A Retrospective Monocentric Study.

Оценочное исследованиеСтатьяResearch Support, N.I.H., IntramuralНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Esengur Omer Tarik, Yilmaz Enis C, Simon Benjamin D, Harmon Stephanie A, Gelikman David G, Lin Yue, Belue Mason J, Merino Maria J, Gurram Sandeep, Wood Bradford J, Choyke Peter L, Pinto Peter A, Turkbey Baris

Аннотация

RATIONALE AND OBJECTIVES: Accurate preoperative mpMRI-based detection of extraprostatic extension (EPE) in prostate cancer (PCa) is critical for surgical planning and patient outcomes. This study aims to evaluate the impact of endorectal coil (ERC) use on the diagnostic performance of mpMRI in detecting EPE.

MATERIALS AND METHODS: This retrospective study with prospectively collected data included participants who underwent mpMRI and subsequent radical prostatectomy for PCa between 2007 and 2024. Participants were divided based on ERC use on mpMRI: MRI without ERC and with ERC. Surgical pathology reports were used to determine the patients with pathologic EPE on whole-mount histopathology. One radiologist evaluated mpMRI using an in-house (National Cancer Institute [NCI]) EPE grading system. Logistic regression (LR) analyses were conducted to identify significant predictors of pathologic EPE, including ERC use and NCI EPE grades.

RESULTS: 934 men (median age: 62 years [IQR = 57-67]) were included. For NCI EPE grade≥1, ERC MRI group (n = 612) had higher NPV (91% [320/353] vs. 83% [166/200], p = 0.01) and sensitivity (75% [101/134] vs. 62% [56/90], p = 0.04) compared to non-ERC group (n = 322). For NCI EPE grade = 3, ERC MRI group had higher NPV (83% [452/546] vs. 75% [221/294], p = 0.01) and accuracy (80% [492/612] vs. 74% [238/322], p = 0.03). In multivariable LR, higher NCI EPE grades were strong independent predictors of pathologic EPE, irrespective of ERC use (NCI EPE grade 2 with ERC: odds ratio [OR] = 2.01, p = 0.04; without ERC: OR = 5.63, p<0.001, NCI EPE grade 3 with ERC: OR = 4.53, p<0.001; without ERC: OR = 5.22, p = 0.002).

CONCLUSION: ERC improves sensitivity, NPV, accuracy of EPE detection with mpMRI at different NCI EPE thresholds. NCI EPE grading system remains the stronger independent predictor of pathologic EPE regardless of ERC use.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049