Maximum lingual pressure impacts both swallowing safety and efficiency in individuals with amyotrophic lateral sclerosis.

Robison Raele Donetha, DiBiase Lauren, Anderson Amber, Wymer James P, Plowman Emily K

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Although reduced lingual strength is a confirmed early manifestation of amyotrophic lateral sclerosis (ALS), its functional impact on swallowing remains unclear. We therefore sought to examine relationships between maximum anterior isometric lingual pressure (MAIP) with swallowing safety, swallowing efficiency, and swallowing timing metrics in a large cohort of individuals with ALS.

METHODS

Ninety-seven participants with ALS completed a standardized videofluoroscopic swallowing examination (VF) and lingual pressure testing (Iowa Oral Performance Instrument). Duplicate and blinded ratings of the Penetration-Aspiration Scale (PAS) and Analysis of Swallowing Physiology: Events, Kinematics and Timing (ASPEKT) percent efficiency (%C2-C42 ) and timing (laryngeal vestibule closure (LVC) duration: amount of time (milliseconds, msec) between LVC onset and laryngeal vestibule opening; time-to-LVC: hyoid burst to onset of LVC (msec); and swallow reaction time: interval between bolus passing ramus of mandible and onset of LVC (msec)) were performed across bolus trials. Swallowing safety (safe PAS: 1, 2, 4; unsafe PAS: 3, 5, 6, 7, and 8) and efficiency (inefficient: ≥3% worst total residue) were derived. Statistical analyses including descriptives, binary logistic regressions, and Spearman's rho correlations were performed (α = 0.05).

KEY

RESULTS

Mean MAIP was 36.3 kPa (SD: 18.7). Mean MAIP was higher in those with safe swallowing as compared to those who penetrated (mean difference: 12 kPa) or aspirated (mean difference: 18 kPa). Individuals with efficient swallowing demonstrated higher MAIP than those with inefficient swallowing (mean difference: 11 kPa). Binary logistic regression analyses revealed increasing MAIP was significantly associated with a 1.06 (95% CI: 1.03-1.09) and 1.04 (95% CI: 1.01-1.06) greater odds of safe and efficient swallowing, respectively. No relationships were observed between MAIP and swallow reaction time across all bolus trials. Longer time-to-LVC (5 ml thin liquid: rs  = -0.35, p = 0.002; cup sip thin liquid: rs  = -0.26, p = 0.02; moderately thick liquid: rs  = -0.28, p = 0.01) and prolonged LVC duration (cup sip thin liquid, rs  = -0.34, p = 0.003) were associated with lower MAIP.

CONCLUSIONS AND INFERENCES: Reduced lingual strength was confirmed in this group of 97 individuals with ALS that was associated with a diminished ability to effectively transport boluses and aide in laryngeal vestibule closure to prevent entry of material into the airway.

Для цитирования: Robison Raele Donetha, DiBiase Lauren, Anderson Amber, Wymer James P, Plowman Emily K. Maximum lingual pressure impacts both swallowing safety and efficiency in individuals with amyotrophic lateral sclerosis.. Neurogastroenterology and motility. 2022. DOI: 10.1111/nmo.14521.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.