DOI 10.1111/micc.12395

Медицинская библиотека · Microcirculation (New York, N.Y. : 1994) · 2017

Between-day reliability of local thermal hyperemia in the forearm and index finger using single-point laser Doppler flowmetry.

McGarr Gregory W, Hodges Gary J, Cheung Stephen S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To assess between-day reliability for LTH in glabrous and nonglabrous index finger skin and nonglabrous forearm skin, with single-point laser Doppler flowmetry.

METHODS

Part-1: In healthy, habitually active males (n=10), LTH was examined twice (~7-10 days apart) for both skin types on the index finger. Part-2: Identical testing was performed on the volar forearm. Local heating (33-42°C at 1°C·20 s-1  + 20 minutes at 44°C) was performed at all skin sites and baseline, initial peak, and plateau phases were identified. Data were expressed as raw CVC (laser-Doppler flux/MAP), and as CVC normalized to baseline (%CVC33°C ) and maximum heating (%CVC44°C ). Reliability was assessed using between-day mean difference, %CV, and ICC.

RESULTS

Reliability (%CV) was poor at baseline for all forms of data presentation and for other phases with %CVC33°C . At the initial peak and plateau, reliability was moderate-poor (20%-26%) for CVC and good-moderate (6%-18%) for %CVC44°C . Reliability was good-moderate for vasodilatory onset time (10%-23%) and time to initial peak (6%-13%).

CONCLUSIONS

For all sites, LTH reliability was acceptable for the timing, and for the initial peak and plateau using CVC or %CVC44°C .

Для цитирования: McGarr Gregory W, Hodges Gary J, Cheung Stephen S. Between-day reliability of local thermal hyperemia in the forearm and index finger using single-point laser Doppler flowmetry.. Microcirculation (New York, N.Y. : 1994). 2017. DOI: 10.1111/micc.12395.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.