MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2026.345570

Медицинская библиотека · Analytica chimica acta · 2026

An automated and portable magnetically-controlled microfluidic chip platform with dual detection modes for sensitive AFP quantification.

Zhang Peng, Zhang Chenqi, Jia Min, Pan Yongdong, Wu Shuo, Cheng Jianxin, Song Lujie, Ming Zizhen

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Early diagnosis of hepatocellular carcinoma (HCC) depends on rapid, sensitive, and reliable immunoassays; however, conventional ELISA techniques are often limited by complex manual operations, prolonged assay durations, and insufficient sensitivity, which significantly impede the detection of low-abundance biomarkers at the early disease stage. In contrast, microfluidic technology minimizes reagent consumption, enables precise spatiotemporal control of reactions, and provides a versatile platform for developing magnetically guided, multi-step immunoassay systems suited for portable, on-site screening applications. Herein, we have developed a portable microfluidic device with magnetic control, wherein an algorithm-driven stepper motor moves the microfluidic chip across a fixed magnetic-field array, thereby creating tunable local magnetic fields. This design integrates digital algorithmic control, mechanical actuation, the microfluidic chip, and functionalized magnetic beads into a seamless control chain, enabling full automation of bead capture, bead transport, and a sequence of immunoreaction steps without manual intervention. Using alpha-fetoprotein (AFP) as a model biomarker, the device achieved a detection limit of 119.43 ng/mL in the colorimetric measurement mode, and an impressive 3.66 ng/mL in the chemiluminescent mode. The results demonstrate the feasibility of automated, multi-step immunoassay processing in a compact point-of-care format, with potential applications in rapid and sensitive biomarker screening for early disease diagnosis. Importantly, this platform substantially fulfils pivotal deficiencies in HCC screening by markedly abbreviating assay duration and attenuating procedural complexity, thereby enhancing accessibility within resource-limited milieus. By facilitating antecedent detection at a juncture when curative interventions are optimally efficacious, it holds considerable promise for elevating patient prognoses, prolonging survival trajectories, and democratizing advanced diagnostic capabilities across broader populations.

Для цитирования: Zhang Peng, Zhang Chenqi, Jia Min, Pan Yongdong, Wu Shuo, Cheng Jianxin, Song Lujie, Ming Zizhen. An automated and portable magnetically-controlled microfluidic chip platform with dual detection modes for sensitive AFP quantification.. Analytica chimica acta. 2026. DOI: 10.1016/j.aca.2026.345570.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.