MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/0115734056263741231117112245

Медицинская библиотека · Current medical imaging · 2024

7 Tesla MRI Liver Fat Quantification in Mice: Data Quality Assessment.

Polei Stefan, Lindner Tobias, Abshagen Kerstin, Liebig Marie, Krause Bernd J, Vollmar Brigitte, Weber Marc-André

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The objective of this study was to evaluate the robustness of proton density fat fraction (PDFF) data determined by magnetic resonance imaging (MRI) and spectroscopy (MRS) via spatially resolved error estimation.

MATERIALS AND

METHODS

Using standard T2* relaxation time measurement protocols, in-vivo and ex-vivo MRI data with water and fat nominally in phase or out of phase relative to each other were acquired on a 7 T small animal scanner. Based on a total of 24 different echo times, PDFF maps were calculated in a magnitude-based approach. After identification of the decisive error-prone variables, pixel-wise error estimation was performed by simple propagation of uncertainty. The method was then used to evaluate PDFF data acquired for an explanted mouse liver and an in vivo mouse liver measurement.

RESULTS

The determined error maps helped excluding measurement errors as cause of unexpected local PDFF variations in the explanted liver. For in vivo measurements, severe error maps gave rise to doubts in the acquired PDFF maps and triggered an in-depth analysis of possible causes, yielding abdominal movement or bladder filling as in vivo occurring reasons for the increased errors.

CONCLUSION

The combination of pixel-wise acquisition of PDFF data and the corresponding error maps allows for a more specific, spatially resolved evaluation of the PDFF value reliability.

Для цитирования: Polei Stefan, Lindner Tobias, Abshagen Kerstin, Liebig Marie, Krause Bernd J, Vollmar Brigitte, Weber Marc-André. 7 Tesla MRI Liver Fat Quantification in Mice: Data Quality Assessment.. Current medical imaging. 2024. DOI: 10.2174/0115734056263741231117112245.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.