Медицинская библиотека · Biosensors & bioelectronics · 2020

PfAgo-based detection of SARS-CoV-2.

Wang Fei, Yang Jun, He Ruyi, Yu Xiao, Chen Shuliang, Liu Yang, Wang Longyu, Li Aitao, Liu Linlin, Zhai Chao, Ma Lixin

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

In the present study, we upgraded Pyrococcus furiosus Argonaute (PfAgo) mediated nucleic acid detection method and established a highly sensitive and accurate molecular diagnosis platform for the large-scale screening of COVID-19 infection. Briefly, RT-PCR was performed with the viral RNA extracted from nasopharyngeal or oropharyngeal swabs as template to amplify conserved regions in the viral genome. Next, PfAgo, guide DNAs and molecular beacons in appropriate buffer were added to the PCR products, followed by incubating at 95 °C for 20-30 min. Subsequently, the fluorescence signal was detected. This method was named as SARS-CoV-2 PAND. The whole procedure is accomplished in approximately an hour with the using time of the Real-time fluorescence quantitative PCR instrument shortened from >1 h to only 3-5 min per batch in comparison with RT-qPCR, hence the shortage of the expensive Real-time PCR instrument is alleviated. Moreover, this platform was also applied to identify SARS-CoV-2 D614G mutant due to its single-nucleotide specificity. The diagnostic results of clinic samples with SARS-CoV-2 PAND displayed 100% consistence with RT-qPCR test.

Для цитирования: Wang Fei, Yang Jun, He Ruyi, Yu Xiao, Chen Shuliang, Liu Yang, Wang Longyu, Li Aitao, Liu Linlin, Zhai Chao, Ma Lixin. PfAgo-based detection of SARS-CoV-2.. Biosensors & bioelectronics. 2020. DOI: 10.1016/j.bios.2020.112932.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.