Clinical validation of quantitative SARS-CoV-2 antigen assays to estimate SARS-CoV-2 viral loads in nasopharyngeal swabs.

Aoki Kotaro, Nagasawa Tatsuya, Ishii Yoshikazu, Yagi Shintaro, Okuma Sadatsugu, Kashiwagi Katsuhito, Maeda Tadashi, Miyazaki Taito, Yoshizawa Sadako, Tateda Kazuhiro

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Expansion of the testing capacity for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is an important issue to mitigate the pandemic of coronavirus disease-2019 (COVID-19) caused by this virus. Recently, a sensitive quantitative antigen test (SQT), Lumipulse® SARS-CoV-2 Ag, was developed. It is a fully automated chemiluminescent enzyme immunoassay system for SARS-CoV-2.

METHODS

In this study, the analytical performance of SQT was examined using clinical specimens from nasopharyngeal swabs using reverse transcription polymerase chain reaction (RT-PCR) as a control.

RESULTS

Receiver operating characteristic analysis of 24 SARS-CoV-2-positive and 524 -negative patients showed an area under the curve of 0.957 ± 0.063. Using a cut-off value of 1.34 pg/ml, the sensitivity was 91.7%, the specificity was 98.5%, and the overall rate of agreement was 98.2%. In the distribution of negative cases, the 99.5 percentile value was 1.03 pg/ml. There was a high correlation between the viral load calculated using the cycle threshold value of RT-PCR and the concentration of antigen. The tendency for the antigen concentration to decrease with time after disease onset correlated with that of the viral load.

CONCLUSIONS

Presented results indicate that SQT is highly concordant with RT-PCR and should be useful for the diagnosis of COVID-19 in any clinical setting. Therefore, this fully automated kit will contribute to the expansion of the testing capability for SARS-CoV-2.

Для цитирования: Aoki Kotaro, Nagasawa Tatsuya, Ishii Yoshikazu, Yagi Shintaro, Okuma Sadatsugu, Kashiwagi Katsuhito, Maeda Tadashi, Miyazaki Taito, Yoshizawa Sadako, Tateda Kazuhiro. Clinical validation of quantitative SARS-CoV-2 antigen assays to estimate SARS-CoV-2 viral loads in nasopharyngeal swabs.. Journal of infection and chemotherapy : official journal of the Japan Society of Chemotherapy. 2020. DOI: 10.1016/j.jiac.2020.11.021.