The accuracy of healthcare worker versus self collected (2-in-1) Oropharyngeal and Bilateral Mid-Turbinate (OPMT) swabs and saliva samples for SARS-CoV-2.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tan Seow Yen, Tey Hong Liang, Lim Ernest Tian Hong, Toh Song Tar, Chan Yiong Huak, Tan Pei Ting, Lee Sing Ai, Tan Cheryl Xiaotong, Koh Gerald Choon Huat, Tan Thean Yen, Siau Chuin
Аннотация
BACKGROUND: Self-sampling for SARS-CoV-2 would significantly raise testing capacity and reduce healthcare worker (HCW) exposure to infectious droplets personal, and protective equipment (PPE) use.
METHODS: We conducted a diagnostic accuracy study where subjects with a confirmed diagnosis of COVID-19 (n = 401) and healthy volunteers (n = 100) were asked to self-swab from their oropharynx and mid-turbinate (OPMT), and self-collect saliva. The results of these samples were compared to an OPMT performed by a HCW in the same patient at the same session.
RESULTS: In subjects confirmed to have COVID-19, the sensitivities of the HCW-swab, self-swab, saliva, and combined self-swab plus saliva samples were 82.8%, 75.1%, 74.3% and 86.5% respectively. All samples obtained from healthy volunteers were tested negative. Compared to HCW-swab, the sensitivities of a self-swab sample and saliva sample were inferior by 8.7% (95%CI: 2.4% to 15.0%, p = 0.006) and 9.5% (95%CI: 3.1% to 15.8%, p = 0.003) respectively. The combined detection rate of self-swab and saliva had a sensitivity of 2.7% (95%CI: -2.6% to 8.0%, p = 0.321). The sensitivity of both the self-collection methods are higher when the Ct value of the HCW swab is less than 30. The specificity of both the self-swab and saliva testing was 100% (95% CI 96.4% to 100%).
CONCLUSION: Our study provides evidence that sensitivities of self-collected OPMT swab and saliva samples were inferior to a HCW swab, but they could still be useful testing tools in the appropriate clinical settings.
METHODS: We conducted a diagnostic accuracy study where subjects with a confirmed diagnosis of COVID-19 (n = 401) and healthy volunteers (n = 100) were asked to self-swab from their oropharynx and mid-turbinate (OPMT), and self-collect saliva. The results of these samples were compared to an OPMT performed by a HCW in the same patient at the same session.
RESULTS: In subjects confirmed to have COVID-19, the sensitivities of the HCW-swab, self-swab, saliva, and combined self-swab plus saliva samples were 82.8%, 75.1%, 74.3% and 86.5% respectively. All samples obtained from healthy volunteers were tested negative. Compared to HCW-swab, the sensitivities of a self-swab sample and saliva sample were inferior by 8.7% (95%CI: 2.4% to 15.0%, p = 0.006) and 9.5% (95%CI: 3.1% to 15.8%, p = 0.003) respectively. The combined detection rate of self-swab and saliva had a sensitivity of 2.7% (95%CI: -2.6% to 8.0%, p = 0.321). The sensitivity of both the self-collection methods are higher when the Ct value of the HCW swab is less than 30. The specificity of both the self-swab and saliva testing was 100% (95% CI 96.4% to 100%).
CONCLUSION: Our study provides evidence that sensitivities of self-collected OPMT swab and saliva samples were inferior to a HCW swab, but they could still be useful testing tools in the appropriate clinical settings.