PURPOSE: This study was designed to evaluate the role of multiparametric magnetic resonance imaging (MRI) for differentiation of parotid gland neoplasms.

METHODS

Prospective study was conducted upon 52 consecutive patients (30 men, 22 women; aged 24-78 years; mean, 51 years) with parotid tumours that underwent multiparametric MRI using combined static MRI, dynamic contrast enhanced (DCE) MRI, and diffusion-weighted imaging (DWI). The static MRI parameter, time signal intensity curves (TIC) derived from DCE-MRI, and apparent diffusion coefficient (ADC) values of parotid tumours were correlated with histopathological findings.

RESULTS

Static MRI revealed a significant difference between both benign and malignant lesions in regards to margin definition (P < .001) and T2 hypointensity (P < .013), with a diagnostic accuracy 95% and 78.33% respectively. Study of the TIC type on DCE-MRI revealed statistically significant difference between benign and malignant lesions (P < .001) and diagnostic accuracy 96.55%. There was no statistically significant difference (P = .181) between the ADC values of benign and malignant lesions. ROC curve analysis revealed that by using ADC cut-off value of 1 × 10-3 mm2/s had accuracy of 84.62% respectively for differentiating Warthin from malignant tumours that could be modified to higher value (94.28%) by excluding lymphoma from malignant lesions. By using cutoff value of 1.3 × 10-3 mm2/s to differentiate pleomorphic adenoma from malignancy, ROC curve analysis had high accuracy of 97.06%.

CONCLUSION

Multiparametric MRI can be used for differentiation of malignant from benign parotid tumours and characterization of some benign parotid tumours.

Для цитирования: Elmokadem Ali H, Abdel Khalek Ahmed M, Abdel Wahab Rihame M, Tharwat Nehal, Gaballa Ghada M, Elata Mohamed Abo, Amer Talal. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging for Differentiation Between Parotid Neoplasms.. Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes. 2019. DOI: 10.1016/j.carj.2018.10.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.