Dynamic MR imaging of the temporomandibular joint using a balanced steady-state free precession sequence at 3T.

Yen P, Katzberg R W, Buonocore M H, Sonico J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The aim of our project was to develop an MR imaging protocol for dynamic imaging of the TMJ. We imaged a total of 24 joints in 12 subjects. We developed an imaging protocol on a 3T system using the true FISP sequence that yielded an acceptable spatial and temporal resolution for dynamic MR imaging.

Для цитирования: Yen P, Katzberg R W, Buonocore M H, Sonico J. Dynamic MR imaging of the temporomandibular joint using a balanced steady-state free precession sequence at 3T.. AJNR. American journal of neuroradiology. 2011. DOI: 10.3174/ajnr.a2734.