Аннотация

BACKGROUND AND AIM: patients with head and neck squamous cell malignancies have a higher risk of oesophageal squamous cell carcinomas. Lugol chromoendoscopy in oesophagus is a simple technique with a high diagnostic yield in premalignant lesions. The objective was to analyze its diagnostic accuracy in dysplasia and carcinoma of the oesophagus in high-risk patients.

METHODS

prospective study from April/2008 to January/2012 using lugol chromoendoscopy with biopsies of suspicious lugol voiding areas > or = 5 mm. Patients with head and neck malignancies were included, except the ones with iodine allergy, oesophageal varices and contra-indications to standard endoscopy. The reference method was histopathology.

RESULTS

89 patients were enrolled (mean age 62.8 + or - 13.3 years, 87 % men). Primary tumour was located in oropharynx in 37 (41.6 %), in oral cavity in 29 (32.6 %) and in the larynx in 23 (25.8 %) cases. 40.4 % patients had previous treatments and 87 % reported alcohol or tobacco addition. All exams performed without anaesthesia or complications. Nine suspicious lugol voiding areas were observed and biopsied. Histopathological analysis revealed high-grade dysplasia in 2 (2.2 %) and inflammation or normal findings in the others. The sensitivity and specificity for detecting high-grade dysplasia were 100 % and 92 % (95 % CI: 87-97), respectively. Diagnostic accuracy of the test was 92 % (95 % CI: 86-98).

CONCLUSION

lugol staining of the oesophagus during endoscopy seems to be a feasible, safe and justified procedure in high-risk populationas it enhances the detection of premalignant lesions.

Для цитирования: Carvalho Rita, Areia Miguel, Brito Daniel, Saraiva Sandra, Alves Susana, Cadime Ana Teresa. Diagnostic accuracy of lugol chromoendoscopy in the oesophagus in patients with head and neck cancer.. Revista espanola de enfermedades digestivas. 2013. DOI: 10.4321/s1130-01082013000200004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.