MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-025-12082-9

Медицинская библиотека · Surgical endoscopy · 2025

Evaluating the ergonomic aspects of laparoscopic energy devices: combination of a survey and a kinesiologic experiment.

Sohn Hee Ju, Song Junkyung, Choi Yoo Shin, Han Youngmin, Kwon Wooil, Park Jaebum, Jang Jin-Young

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

This study aimed to evaluate surgeons' ergonomic satisfaction when using laparoscopic energy devices and to investigate how prolonged use affects muscle fatigue and surgical performance.

METHODS

A two-part study, including a survey and a kinesiologic experiment, was conducted to compare 4 laparoscopic energy devices (D1-D4). Thirty surgeons completed a structured survey assessing ergonomic factors such as device weight, grip strength, handle design, comfort, and trigger location. In parallel, a kinesiologic experiment involving 20 surgeons measured device activation force, surface electromyography (EMG) changes, and targeting accuracy before and after fatigue induction using a standardized protocol.

RESULTS

The survey revealed significant ergonomic differences among devices. In the kinesiologic study, two devices showed a significant decline in precision and targeting accuracy after fatigue. All but one device demonstrated significant changes in the median frequency (MDF) and integrated EMG (iEMG) of the flexor digitorum superficialis muscle (P < 0.001), indicating muscle fatigue.

CONCLUSION

Prolonged use of certain laparoscopic energy devices induces muscle fatigue and impairs accuracy. These findings underscore the importance of ergonomic considerations in surgical instrument design to enhance surgeon performance and reduce fatigue-related risks.

Для цитирования: Sohn Hee Ju, Song Junkyung, Choi Yoo Shin, Han Youngmin, Kwon Wooil, Park Jaebum, Jang Jin-Young. Evaluating the ergonomic aspects of laparoscopic energy devices: combination of a survey and a kinesiologic experiment.. Surgical endoscopy. 2025. DOI: 10.1007/s00464-025-12082-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.