MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/uog.20178

Медицинская библиотека · Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2019

Echogenicity of puborectalis muscle, cervix and vastus lateralis muscle in pregnancy in relation to mode of delivery.

Van de Waarsenburg M K, Withagen M I J, van den Noort F, Schagen van Leeuwen J H, van der Vaart C H

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

To confirm our previous observation that levator hiatal dimensions and mean echogenicity of the puborectalis muscle (MEP) are significantly different at 12 weeks' gestation in women who delivered by Cesarean section due to failure to progress compared with those who delivered vaginally. The secondary objective was to assess the association between the echogenicity of the cervix and vastus lateralis muscle and mode of delivery.

METHODS

In this prospective multicenter study, 306 nulliparous women with a singleton pregnancy underwent ultrasound assessments of the pelvic floor at rest, on maximum pelvic floor muscle contraction and on maximum Valsalva maneuver, of the cervix and of the vastus lateralis muscle at 12 weeks' gestation. Dimensions of the levator hiatus, MEP and mean echogenicity of the cervix and vastus lateralis muscle were measured and compared according to mode of delivery.

RESULTS

Two hundred and forty-nine women were included in the analyses. We were unable to confirm our previous finding that MEP and levator hiatal transverse diameter and area at 12 weeks' gestation are associated significantly with mode of delivery. In addition, we could not demonstrate a significant association between echogenicity of the cervix or vastus lateralis muscle and mode of delivery. Overall, MEP was a mean of 20 points lower in women in the new database as compared with the previous study, despite the use of the same ultrasound equipment.

CONCLUSION

In a second, independent multicenter dataset, we were unable to confirm our previous finding that levator hiatal dimensions and MEP on pelvic floor muscle contraction are associated significantly with mode of delivery. We also found no association between echogenicity of the cervix or vastus lateralis and mode of delivery. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

Для цитирования: Van de Waarsenburg M K, Withagen M I J, van den Noort F, Schagen van Leeuwen J H, van der Vaart C H. Echogenicity of puborectalis muscle, cervix and vastus lateralis muscle in pregnancy in relation to mode of delivery.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2019. DOI: 10.1002/uog.20178.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.