m+Medelevator.RU
← Поиск публикаций
Journal of gastroenterology · 2023

New chemiluminescent enzyme immunoassay for quantitative measurement of Mac-2 binding protein glycosylation isomer in chronic liver disease.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Uojima Haruki, Nakabayashi Kadzuki, Yamasaki Kazumi, Sugiyama Masaya, Ishii Norihiro, Shirabe Ken, Kyoutou Takuya, Ueda Koji, Takahama Yoichi, Tamaki Nobuharu, Kurosaki Masayuki, Hidaka Hisashi, Kusano Chika, Amano Keisuke, Kawaguchi Takumi, Taketomi Akinobu, Joshita Satoru, Umemura Takeji, Murakawa Miyako, Asahina Yasuhiro, Suzuki Takanori, Matsuura Kentaro, Nishimura Takashi, Iijima Hiroko, Sakamoto Kazumasa, Ito Kiyoaki, Nishina Sohji, Hino Keisuke, Toyoda Hidenori, Yatsuhashi Hiroshi, Kage Masayoshi, Mizokami Masashi

Аннотация

BACKGROUND: This study aimed to evaluate the quantitative measurement of Mac-2 binding protein glycosylation isomer (M2BPGi) levels using the new chemiluminescent enzyme immunoassay.

METHODS: The data of a total of 347 patients with hepatitis C virus (HCV) infection and 150 health volunteers from 13 locations in Japan were evaluated. The quantitative system for measuring M2BPGi-Qt levels was based on a new chemiluminescent enzyme immunoassay. We evaluated the reproducibility and quantitation range in quantitative M2BPGi-Qt measurement. We also investigated the confidence ratio of M2BPGi-Qt levels measured by the new quantitative system to M2BPGi levels measured by the current semi-quantitative system for validating the clinical utility of the new method.

RESULTS: The reproducibility of M2BPGi-Qt in HCV samples with negative, positive 1+, and positive 2+ was 0.77 ± 0.02 AU/mL, 2.25 ± 0.03 AU/mL, and 6.55 ± 0.21 AU/mL, respectively, and the corresponding coefficient of variation (CV)s were 2.1%, 1.3%, and 3.2%, respectively. The range of quantification assessment resulted that all CVs showed less than 5% in investigated range. Sample stability testing found that the mean percentage difference between the pre- and post-storage values of 6 samples ranged between 96.2 and 103.9%. The correlation coefficient between M2BPGi and M2BPGi-Qt in patients with HCV and the healthy volunteers was 0.986 and 0.991, respectively. M2BPGi-Qt could be quantitatively assessed in a patient with over 20 C.O.I.

CONCLUSION: Compared with qualitative methods, the M2BPGi quantitative measurement system could provide a numerical value unaffected by interpretation bias, and measurements are more precise at high M2BPGi levels.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты