Huang Li, Zhou Guang, Wang Xi-Tao, Li Guo-Guang, Li Guang-Yi
Аннотация
PURPOSE: To evaluate the diagnostic accuracy of abdominal contrast-enhanced multi-slice spiral CT after oral diluted iodide in a time segment (post-ODI ACE-MSCT) for gastrointestinal fistula (GIF) in severe acute pancreatitis (SAP).
MATERIALS AND METHODS: Patients with SAP who underwent both post-ODI ACE-MSCT and endoscopy/surgery from 2017 to 2023 were continuously retrospectively involved. Their demographic information and clinical features were recorded prospectively in an in-hospital database. Using endoscopy/surgery results as the reference standard, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of post-ODI ACE-MSCT for diagnosing GIF in SAP were calculated by a four-cell table. The consistency of the two diagnostic methods was evaluated by the Kappa test and McNemar's test.
RESULTS: Using endoscopy/surgery as the reference standard, a total of 86 cases were divided into the GIF group (N = 52) and the non-GIF group (N = 34). Among the 52 cases of GIF, 88.5% (46/52) cases had a positive result and 11.5% (5/52) cases had a negative result of post-ODI ACE-MSCT for GIF. Among the 34 cases of non-GIF, 2.9% (1/34) case had a positive result and 97.1% (33/34) cases had a negative result of post-ODI ACE-MSCT for GIF. Post-ODI ACE-MSCT had a sensitivity of 88.5% (95% CI 75.9%-95.2%), a specificity of 97.1% (95% CI 82.9%-99.8%), a positive predictive value of 97.9% (95% CI 87.3%-99.9%), a negative predictive value of 84.6% (95% CI 68.8%-93.6%), and an accuracy of 91.9% (83.4%-96.4%). The kappa value was 0.834, and P < 0.001 by McNemar's test. There were no significant differences in diagnostic test characteristics between the two modalities.
CONCLUSION: Post-ODI ACE-MSCT can diagnose GIF in SAP in a simple, noninvasive, and accurate way, and can provide earlier imaging evidence for clinical diagnosis and treatment.
MATERIALS AND METHODS: Patients with SAP who underwent both post-ODI ACE-MSCT and endoscopy/surgery from 2017 to 2023 were continuously retrospectively involved. Their demographic information and clinical features were recorded prospectively in an in-hospital database. Using endoscopy/surgery results as the reference standard, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of post-ODI ACE-MSCT for diagnosing GIF in SAP were calculated by a four-cell table. The consistency of the two diagnostic methods was evaluated by the Kappa test and McNemar's test.
RESULTS: Using endoscopy/surgery as the reference standard, a total of 86 cases were divided into the GIF group (N = 52) and the non-GIF group (N = 34). Among the 52 cases of GIF, 88.5% (46/52) cases had a positive result and 11.5% (5/52) cases had a negative result of post-ODI ACE-MSCT for GIF. Among the 34 cases of non-GIF, 2.9% (1/34) case had a positive result and 97.1% (33/34) cases had a negative result of post-ODI ACE-MSCT for GIF. Post-ODI ACE-MSCT had a sensitivity of 88.5% (95% CI 75.9%-95.2%), a specificity of 97.1% (95% CI 82.9%-99.8%), a positive predictive value of 97.9% (95% CI 87.3%-99.9%), a negative predictive value of 84.6% (95% CI 68.8%-93.6%), and an accuracy of 91.9% (83.4%-96.4%). The kappa value was 0.834, and P < 0.001 by McNemar's test. There were no significant differences in diagnostic test characteristics between the two modalities.
CONCLUSION: Post-ODI ACE-MSCT can diagnose GIF in SAP in a simple, noninvasive, and accurate way, and can provide earlier imaging evidence for clinical diagnosis and treatment.