[Virtual endoscopy of the urinary tract from T(2)-weighted and gadolinium-enhanced T(1)-weighted MR urographic images].

Beer A, Saar B, Link T M, Settles M, Drews C, Schwaibold H, Rummeny E J

Сравнительное исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the diagnostic performance of T(2)-weighted (T2w) and gadolinium-enhanced T(1)-weighted (T1w-Gd-enhanced) MR urographic images for virtual endoscopy of the urinary tract.

MATERIALS AND

METHODS

36 patients underwent MR urography at 1.5 T. In each patient a T2w (3D-TSE, respiration-triggered) and a T1w-Gd-enhanced sequence (T1-FFE, breathhold) were acquired. Data reconstruction was performed as maximum intensity projection (MIP) and virtual endoscopy (VE).

RESULTS

Combined analysis of MIP and VE delineated 32 of 36 pathologies; 86 % (19/22) of intraluminal pathologies could be depicted by VE and 15 % (3/22) by MIP (p </= 0.01). For the assessment of the renal pelvis, MIP was superior to VE in 55 % (39/71). Concerning the ureter, MIP was equal in 52 % (37/71) and superior to VE in 45 % (32/71). For virtual ureterorenoscopy both data sets were comparable in their diagnostic performance. T2w data sets were superior for virtual cystoscopy because no contrast medium is required in cases of renal failure and sedimentation artifacts can be avoided.

CONCLUSION

For the depiction of the upper urinary tract, MIP is in most cases equally good or superior to VE. However, virtual endoscopy of the urinary tract, especially virtual cystoscopy, is a useful tool for the depiction of intraluminal pathology.

Для цитирования: Beer A, Saar B, Link T M, Settles M, Drews C, Schwaibold H, Rummeny E J. [Virtual endoscopy of the urinary tract from T(2)-weighted and gadolinium-enhanced T(1)-weighted MR urographic images].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2001. DOI: 10.1055/s-2001-18317.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.