MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/jop.2019.0038

Медицинская библиотека · Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics · 2019

Fluorophotometric Assessment of Tear Volume and Turnover Rate in Healthy Dogs and Cats.

Sebbag Lionel, Allbaugh Rachel A, Wehrman Rita F, Uhl Lisa K, Ben-Shlomo Gil, Chen Thomas, Mochel Jonathan P

СтатьяПеревод пока не подготовлен

Аннотация

Purpose: The study establishes normative data of tear volume (TV) and tear turnover rate (TTR) in healthy dogs and cats, 2 species commonly used for translational research in ophthalmology.

Methods

Thirty-six dogs and 24 cats were enrolled, encompassing a variety of breeds with diverse skull conformations (brachycephalic, mesocephalic, and dolichocephalic). Two microliters of 10% fluorescein were instilled onto the upper bulbar conjunctiva of both eyes, followed by tear collection with 2-μL capillary tubes at 0, 2, 4, 6, 10, 15, and 20 min. Fluorescein concentrations were measured with a computerized scanning ocular fluorophotometer. The TV and TTR were estimated based upon nonlinear mixed-effects analysis of fluorescein decay curves.

Results

In dogs, median (interquartile range) TV, basal TTR (bTTR), and reflex TTR (rTTR) were 65.3 μL (42.3-87.9), 12.2%/min (3.7-22.1), and 50.0%/min (25.9-172.3), respectively. In cats, median (interquartile range) TV, bTTR, and rTTR were 32.1 μL (29.5-39.9), 10.9%/min (3.0-23.7), and 50.0%/min (28.4-89.4), respectively. Body weight (r = 0.44) and age (r = 0.30) were positively correlated (P ≤ 0.019) with TV in dogs. Age was negatively correlated (P ≤ 0.018) with TTR in dogs (r = -0.33) and cats (r = -0.24). However, TV and TTR were not associated with skull conformation in either species.

Conclusions

Dogs have greater TV than cats but similar basal and rTTR. Tear parameters were impacted by body weight and age, but not by skull conformation. In both clinical and research settings, successive lacrimal tests should be spaced by ≥10 min to provide sufficient time for the tear film to replenish, as bTTR is ∼11%/min-12%/min in both species.

Для цитирования: Sebbag Lionel, Allbaugh Rachel A, Wehrman Rita F, Uhl Lisa K, Ben-Shlomo Gil, Chen Thomas, Mochel Jonathan P. Fluorophotometric Assessment of Tear Volume and Turnover Rate in Healthy Dogs and Cats.. Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics. 2019. DOI: 10.1089/jop.2019.0038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.