DOI 10.1016/j.mvr.2019.103907

Медицинская библиотека · Microvascular research · 2019

Quantitative assessment of the conjunctival microcirculation using a smartphone and slit-lamp biomicroscope.

Brennan Paul F, McNeil Andrew J, Jing Min, Awuah Agnes, Finlay Dewar D, Blighe Kevin, McLaughlin James A D, Wang Ruixuan, Moore Jonathan, Nesbit M Andrew, Trucco Emanuele, Spence Mark S, Moore Tara C B

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The conjunctival microcirculation is a readily-accessible vascular bed for quantitative haemodynamic assessment and has been studied previously using a digital charge-coupled device (CCD). Smartphone video imaging of the conjunctiva, and haemodynamic parameter quantification, represents a novel approach. We report the feasibility of smartphone video acquisition and subsequent haemodynamic measure quantification via semi-automated means.

METHODS

Using an Apple iPhone 6 s and a Topcon SL-D4 slit-lamp biomicroscope, we obtained videos of the conjunctival microcirculation in 4 fields of view per patient, for 17 low cardiovascular risk patients. After image registration and processing, we quantified the diameter, mean axial velocity, mean blood volume flow, and wall shear rate for each vessel studied. Vessels were grouped into quartiles based on their diameter i.e. group 1 (<11 μm), 2 (11-16 μm), 3 (16-22 μm) and 4 (>22 μm).

RESULTS

From the 17 healthy controls (mean QRISK3 6.6%), we obtained quantifiable haemodynamics from 626 vessel segments. The mean diameter of microvessels, across all sites, was 21.1μm (range 5.8-58 μm). Mean axial velocity was 0.50mm/s (range 0.11-1mm/s) and there was a modestly positive correlation (r 0.322) seen with increasing diameter, best appreciated when comparing group 4 to the remaining groups (p < .0001). Blood volume flow (mean 145.61pl/s, range 7.05-1178.81pl/s) was strongly correlated with increasing diameter (r 0.943, p < .0001) and wall shear rate (mean 157.31 s-1, range 37.37-841.66 s-1) negatively correlated with increasing diameter (r - 0.703, p < .0001).

CONCLUSIONS

We, for the first time, report the successful assessment and quantification of the conjunctival microcirculatory haemodynamics using a smartphone-based system.

Для цитирования: Brennan Paul F, McNeil Andrew J, Jing Min, Awuah Agnes, Finlay Dewar D, Blighe Kevin, McLaughlin James A D, Wang Ruixuan, Moore Jonathan, Nesbit M Andrew, Trucco Emanuele, Spence Mark S, Moore Tara C B. Quantitative assessment of the conjunctival microcirculation using a smartphone and slit-lamp biomicroscope.. Microvascular research. 2019. DOI: 10.1016/j.mvr.2019.103907.