Contact lens & anterior eye : the journal of the British Contact Lens Association · 2019

Best technique for upper lid eversion.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wolffsohn James S, Tahhan Mohammed, Vidal-Rohr Maria, Hunt Olivia A, Bhogal-Bhamra Gurpreet

Аннотация

AIM: Lid eversion is an essential component of contact lens aftercare. Hence, this study determined the best method of lid eversion based on three criteria: comfort, speed of administration and the area of the palpebral conjunctiva exposed.

METHOD: Twenty-five participants (aged 20-34) had 6 different techniques applied in random order by the same clinician on two separate occasions: three involving a cotton bud placed on the extended upper eyelid either centrally, at the top of the tarsal plate or off-centre; one using the wooden end of the bud placed at the top of the tarsal plate; one using the clinician's index finger to evert the lid; and one using a silicone rubber, finger-shaped substitute. The participants judged the degree of discomfort of each technique on a visual analogue scale. The time to complete the task was timed with a stop-watch and the area of exposed palpebral conjunctiva was captured with a digital slit lamp and assessed using image analysis.

RESULTS: There was no difference between the initial lid eversion or subsequent repeat in terms of comfort (F = 0.304, p = 0.586), time to complete (F = 3.075, p = 0.092) or area exposed (F = 2.311, p = 0.142). Lid eversion using fingers alone or the silicone substitute everter were similar in comfort (p = 0.312), being the most comfortable methods, with off-centre cotton bud eversion or the wooden end of the cotton bud the least comfortable techniques (F = 17.480, p < 0.001). The quickest method to perform was the wooden end of the cotton bud, followed by the silicone everter (F = 17.522, p < 0.001). The area of exposed palpebral conjunctiva was greatest using the silicone everter (F = 28.199, p < 0.001).

CONCLUSIONS: Lid eversion had repeatable results, with the silicone everter placed at the top of the tarsal plate the most comfortable for the patient, quick to perform and exposed a greater area of tarsal plate than other techniques and therefore is recommended to clinicians.