MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3341/kjo.2024.0093

Медицинская библиотека · Korean journal of ophthalmology : KJO · 2024

The Effect of Lower Eyelid Blepharoplasty on Corneal Biomechanical Parameters.

Rafizadeh Seyed Mohsen, Hashemian Hesam, Khorrami-Nejad Masoud, Hadi Ali, Ghochani Ghazal

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the effect of lower eyelid blepharoplasty (LEB) surgery on corneal biomechanical parameters before and 4 months after the procedure.

METHODS

In this prospective longitudinal study, corneal biomechanical parameters measured by Corneal Visualization Scheimpflug Technology device were evaluated before and 4 months after LEB surgery.

RESULTS

The study included 19 eyelids of the right eyes of 19 patients who underwent LEB, with a mean age of 49.0 ± 10.1 years (range, 37-72 years). Four months after the procedure, significant increases were observed in the first applanation time (p = 0.007), second applanation time (p < 0.001), highest concavity time (p = 0.004), intraocular pressure (p = 0.009), and biomechanical-compensated intraocular pressure (p = 0.007). In addition, the absolute value of highest concavity delta arc length and stress-strain index showed a significant decrease after the LEB (p = 0.021 and p = 0.037, respectively). Other corneal biomechanical parameters did not show significant differences following the LEB procedure (p < 0.05).

CONCLUSIONS

The resection and repositioning of the fat pockets in LEB lead to biomechanical changes of the cornea in the direction of increasing corneal stiffness.

Для цитирования: Rafizadeh Seyed Mohsen, Hashemian Hesam, Khorrami-Nejad Masoud, Hadi Ali, Ghochani Ghazal. The Effect of Lower Eyelid Blepharoplasty on Corneal Biomechanical Parameters.. Korean journal of ophthalmology : KJO. 2024. DOI: 10.3341/kjo.2024.0093.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.