MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18240/ijo.2024.11.01

Медицинская библиотека · International journal of ophthalmology · 2024

Knockout of TMEM206 in mice associated with a loss of corneal transparency.

Yang Zi-Jian, Huang Shou-Yue, Zhou Yu-Feng, Sun Shun-Chang

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To investigate the role of transmembrane protein 206 (TMEM206) in corneal edema in mice by knockout the TMEM206 gene using CRISPR/Cas9 editing technology.

METHODS

TMEM206-knockout mice were generated using the CRISPR-Cas9 system. Variations in ophthalmic pathology were observed using slit lamp microscope and optical coherence tomography (OCT), intraocular pressure (IOP) was measured using a TonoLab Rebound Tonometer, and the ultrastructure of the corneal was observed using a transmission electron microscope.

RESULTS

Corneal opacity was observed in 4/18 homozygous TMEM206-/- mice whereas a similar change was not observed in heterozygous TMEM206+/- mice and wild-type littermates. OCT examination showed that the mean central cornea thickness was 125±5.4 µm in 4 homozygous TMEM206-/- mice developed corneal edema and 115±1.2 µm in wild-type mice (t=3.468, P<0.05) at 43wk. The mean IOP was 12.08±0.07 mm Hg in four right eyes with corneal edema and 12.03±0.03 mm Hg in three normal left eyes (P>0.05). Transmission electron microscopy revealed a disruption in the organization of the collagen fibrils in the central part of the cornea in homozygous TMEM206-/- mice.

CONCLUSION

TMEM206 is associated with corneal edema which caused organizational disruption of collagen fibrils in corneas of mice.

Для цитирования: Yang Zi-Jian, Huang Shou-Yue, Zhou Yu-Feng, Sun Shun-Chang. Knockout of TMEM206 in mice associated with a loss of corneal transparency.. International journal of ophthalmology. 2024. DOI: 10.18240/ijo.2024.11.01.